📌 Key Takeaways
- •[A-S1] Murata — Murata NCP18XH103F03RB product search datasheet: 10 kΩ ±1% NTC, B25/50 3380 K ±1%, -40 to 125°C — https://static6.arrow.com/aropdfconversion/dcfdcdc58f3f5e7aa5ea0fcd1af134580e122fae/ncp18xh103f03rb.pdf
- •[A-S2] EDN — EDN: NTC Thermistor Beta & Steinhart-Hart Guide — IEC 60539, -2 to -6%/K, Beta vs Steinhart-Hart equations — https://www.edn.com/ntc-thermistor-beta-steinhart-hart-guide/
- •[A-S3] The Science 360 — The Science 360: NTC Thermistor Calculation Beta vs Steinhart-Hart — Vishay NTCLE100E3103 B25/85 3977 K, Beta error ±0.4°C, Steinhart-Hart ±0.035°C — https://thescience360.com/ntc-thermistor-beta-equation/
- •[A-S4] Vishay — Vishay NTCLE100E3 datasheet (Doc. 29049) pp. 4-6: R-T tables, B25/85 3977 K for 10 kΩ, extended Steinhart-Hart coefficients — https://www.omo-ic.com/pdf/716493/ntcle100e3472jt1-vishay/P4-P6.html
- •[A-S5] Semitec — Semitec AT Thermistor datasheet: 103AT-2/3/5, 10.0 kΩ, B25/85 3435 K ±1%, R-T table (27.28 kΩ at 0°C) — https://www.mouser.pe/datasheet/2/362/P12_13_AT_Thermistor-2320347.pdf
# Laptop Battery Temperature Sensor Failure: An Advanced Guide to NTC Thermistors, JEITA Bands, and Layered Diagnosis
Plug in the adapter, and the machine says it is charging, yet the battery percentage stops at sixty percent and never moves. Start from cold and it charges, then after a while, once the machine warms up, it changes to not charging, and after a night left to cool it charges again. These on-and-off patterns, charging that stops only under certain conditions, lead many users to blame an aged battery or a dead charging chip, but behind them can sit one very small part telling a lie: the battery temperature sensor. The sensor itself neither charges nor counts charge; it turns battery temperature into a resistance value, then into a voltage, and hands that voltage to the charging chip and the fuel gauge chip to judge. When the witness speaks wrongly, both sides decide wrongly. This guide starts with the sensor itself, then works through the resistance and temperature curve, the divider circuit, the JEITA temperature bands, the four-layer temperature path, failure physics, a symptom map, eight layers of diagnosis, misdiagnosis traps, Hong Kong conditions, and the repair or replace decision, so that a user can tell symptoms apart, ask the right questions, and check the work before sending a machine in.
Introduction: A Symptom Is Not a Diagnosis
Not charging is a symptom, not a diagnosis. Behind that one sentence can sit an adapter with no output, a loose socket, a charging chip that cannot detect the adapter, a fuel gauge chip reporting an error, a locked battery protection board, an embedded controller that never wrote the charge parameters, or a temperature sensor reading the wrong temperature. The mark of a temperature sensor fault is charging that stops only under certain conditions: on and off, stopping at a percentage that changes each time, charging when cold and stopping when hot, then charging again after cooling down. When nothing charges at any temperature, the sensor is only one suspect among several [B-S33][A-S53][B-S32].
Layered exclusion means working from the outside in, from cheap to costly, and from checks that need no disassembly to those that do, narrowing the fault layer by layer. First check the maker charge limit settings, then read the Windows and BIOS figures, then cross-test with a known good battery of the same model, and only at the end measure sensor resistance and the temperature sense pin voltage. Until one layer is ruled out, no conclusion should be drawn about the next. The special trouble with temperature faults is that the witness itself can lie: sensor, divider resistor, fuel gauge, and embedded controller are four witnesses, and when any one of them speaks wrongly, the charging chip decides wrongly [A-S43][B-S33][A-S34].
The diagnostic order in this guide applies to Windows laptops, while Apple machines use a different battery management architecture, so their diagnosis must be checked against the matching maker documents. The temperature thresholds, voltage percentages, and resistance values quoted here apply only to the chip designs named, and must never be carried across to other models. Back up data before measuring anything, since a sensor fault can shut a laptop down without warning, and unsaved work may be lost [B-S33][A-S15][A-S53].
Not charging is a symptom, not a diagnosis, and that reminder belongs at the very front of diagnosis. The layers start with checks that need no disassembly, then move deeper to the communication layer and board-level measurement, each with its own tools and judgement rules, and skipping layers to swap parts directly is the most expensive and least accurate move [B-S33][A-S53][B-S32].
Layered exclusion means working from the outside in, from cheap to costly, and from checks that need no disassembly to those that do, narrowing the fault layer by layer. Cross-testing changes only one variable at a time, and changing two or more variables at once makes the result impossible to explain [B-S33][B-S40][B-S34].
Not charging is a symptom, not a diagnosis. The layers start with checks that need no disassembly, then move deeper to the communication layer and board-level measurement, and skipping layers to swap parts directly is the most expensive and least accurate move [B-S33][B-S49][B-S32].
For charges, see pricing; for the diagnostic route, see diagnostics.
What an NTC Thermistor Is: A Negative Temperature Coefficient Ceramic Semiconductor
An NTC thermistor is a temperature-sensitive semiconductor resistor whose resistance falls as temperature rises; under the IEC 60539 definition, it is a thermally sensitive semiconductor resistor made from transition metal oxides. Mainstream NTC parts use spinel-type nickel manganese oxide ceramic, conducting through thermally activated charge carriers, with raw materials of manganese, iron, cobalt, nickel, copper, and zinc oxides, formed and then sintered above roughly one thousand degrees [A-S2][A-S10].
The large temperature coefficient is what makes the NTC suited to battery temperature sensing. The negative temperature coefficient of an NTC runs near minus 2 to minus 6 percent per degree, roughly ten times that of a metal and five times that of a silicon temperature sensor, and one 10 kilohm probe is rated at minus 3.90 percent per degree. A difference of a few degrees already moves the resistance visibly [A-S2][A-S14].
The difference from a PTC must be kept clear: with an NTC, resistance falls as temperature rises, while with a PTC, resistance rises as temperature rises, and a switching PTC jumps sharply past its switching temperature. Battery temperature sensing uses NTC parts only, never PTC parts. An NTC is not a precision resistor but a curve part: the resistance and temperature relationship follows an exponential curve, not a straight line, so every temperature reading must come from a curve model or the maker resistance-temperature table, never from a straight-line proportion [A-S10][A-S2][A-S3].
An NTC is not a precision resistor but a curve part, with resistance and temperature following an exponential curve, so every temperature reading must come from a curve model or the maker resistance-temperature table, never from a straight-line proportion [A-S2][A-S3][A-S10].
An NTC is a curve part, and makers list the resistance-temperature curve as a temperature and resistance ratio table, with Beta values covering 2700 K to 4400 K, so converting between parts with different Beta values must use the matching table [A-S6][A-S2].
The charging chip does not use the Beta equation, since it compares voltages against fixed thresholds, but when the fuel gauge chip reads temperature through its converter, the firmware converts with a resistance-temperature table or a Steinhart-Hart style model [A-S35][A-S39][A-S3].
| Item | NTC | PTC |
|---|---|---|
| Resistance as temperature rises [A-S10] | Falls | Rises |
| Temperature coefficient [A-S2] | Minus 2 to 6 percent per degree | Positive, switching types jump sharply |
| Battery temperature sensing [A-S10] | This type is used | This type is not used |
| Conversion method [A-S3] | Curve model or lookup table | Not applicable |
R25 and the B Value: Two Numbers Define One NTC
One NTC part is mainly defined by two numbers: R25, the zero-power resistance at 25 degrees, and the B value, the material constant that sets the slope of the curve, while tolerance and dissipation constant then set accuracy and response speed. Laptop battery packs most often use 10 kilohms: the Murata NCP18XH103F03RB is 10 kilohms plus or minus 1 percent, the Semitec 103AT-2 is 10.0 kilohms plus or minus 1 percent, and the Panasonic ERTJ1VG103 series is also 10 kilohms [A-S2][A-S1][A-S5][A-S13].
The B value is not one fixed material constant; it is a two-point fit defined by two calibration temperatures, and the subscript says which two temperatures those are. For the same Vishay NTCLE100E3103, different temperature pairs give different values: B0/25 is 3845 K, B25/50 is 3932 K, B25/85 is 3977 K, and B25/100 is 3994 K, a spread of about 4 percent. Whenever a B value is quoted, the subscript must travel with it, never a bare number alone [A-S3].
Common B values stand for three curves with different slopes, and they cannot be swapped. The 103AT uses B25/85 of 3435 K plus or minus 1 percent, the Murata XH series uses B25/50 of 3380 K plus or minus 1 percent, the Vishay NTCLE100E3103 uses B25/85 of 3977 K plus or minus 0.75 percent, and a general 10 kilohm B3950 probe uses B25/50 of 3950 K plus or minus 1 percent. With the wrong B value, the reading at 25 degrees can look correct while the reading in the hot band sits several degrees out [A-S5][A-S1][A-S4][A-S7][A-S3].
Whenever a B value is quoted, the subscript must travel with it, never a bare number alone. For the same Vishay part, different temperature pairs give B0/25 of 3845 K and B25/85 of 3977 K, a spread of about 4 percent [A-S3][A-S4].
Common B values stand for three curves with different slopes, and they cannot be swapped. The 103AT uses B25/85 of 3435 K, the Murata XH uses B25/50 of 3380 K, and the Vishay part uses B25/85 of 3977 K [A-S5][A-S1][A-S4].
The complete temperature path starts at the pack-inside NTC, runs through the gauge, the charging chip, and the embedded controller, and ends at the Windows screen. When any layer goes wrong, the screen can show no charging [A-S34][A-S43][A-S45].
| Part | R25 | B value |
|---|---|---|
| Semitec 103AT [A-S5] | 10.0 kilohms | B25/85 3435 K |
| Murata NCP18XH103 [A-S1] | 10 kilohms | B25/50 3380 K |
| Vishay NTCLE100E3103 [A-S4] | 10 kilohms | B25/85 3977 K |
| General B3950 probe [A-S7] | 10 kilohms | B25/50 3950 K |
Quantified R-T Tables: Measured Numbers for Three Mainstream Curves
The numbers below all come from maker resistance-temperature tables or from openly published calculation checked against the Beta equation, and any quotation should name which curve it belongs to. For the same 10 kilohm NTC, different B values can move the resistance at 0 degrees and at 50 degrees by a fifth. The Vishay NTCLE100E3103, with B25/85 of 3977 K, reads 332.1 kilohms at minus 40 degrees, 96.36 kilohms at minus 20 degrees, 32.56 kilohms at 0 degrees, 19.87 kilohms at 10 degrees, 10.00 kilohms at 25 degrees, 5.330 kilohms at 40 degrees, 3.606 kilohms at 50 degrees, and 2.989 kilohms at 55 degrees [A-S4][A-S3].
The Semitec 103AT, with B25/85 of 3435 K, is the reference NTC for TI charging chips: 27.28 kilohms at 0 degrees, 10.00 kilohms at 25 degrees, and 3.02 kilohms at 60 degrees, and the TI BQ25619 datasheet lists those two end numbers plainly. At the same temperature, the 103AT resistance sits clearly below the B3977 part, 27.28 kilohms against 32.56 kilohms at 0 degrees, so the charging chip temperature sense divider must be designed around the 103AT, and fitting an NTC with the wrong B value shifts the whole JEITA threshold set [A-S5][A-S21].
The general 10 kilohm B3950, with B25/50 of 3950 K, reads about 32.1 kilohms at 0 degrees and 3.588 kilohms at 50 degrees by Beta equation check, against 3.592 kilohms in the maker table. One circulating estimate must be corrected here: the claim that a 10 kilohm NTC reads about 3.3 kilohms at 50 degrees is wrong, since measurement and calculation both give about 3.59 kilohms, and 3.3 kilohms understates the value by about 8 percent. This guide uses 3.59 kilohms throughout, never 3.3 kilohms. The Murata NCP18XH103, with B25/50 of 3380 K, reads 28.674 kilohms at 0 degrees and 10.00 kilohms at 25 degrees, a curve sitting between the 103AT and the B3977 part [A-S7][A-S8][A-S1][A-S11].
For the same 10 kilohm NTC, different B values can move the resistance at 0 degrees and at 50 degrees by a fifth. Any quotation should name which curve it belongs to, never carrying one table across to parts with different B values [A-S6][A-S4][A-S5].
Maker resistance-temperature tables are the baseline for measurement judgement: the 103AT reads 27.28 kilohms at 0 degrees and 3.02 kilohms at 60 degrees, the B3977 reads 32.56 kilohms at 0 degrees and 3.606 kilohms at 50 degrees, and the B3950 reads 3.59 kilohms at 50 degrees [A-S21][A-S4][A-S7].
The intuitive feel of the temperature coefficient is that a 10 kilohm NTC near 25 degrees loses about 3.9 percent of resistance per degree rise, with a steeper slope near 0 degrees and a flatter slope near 60 degrees [A-S14][A-S2].
| Temperature | 103AT B3435 [A-S5] | B3977 [A-S4] | B3950 [A-S7] | XH103 B3380 [A-S1] |
|---|---|---|---|---|
| 0 degrees | 27.28 kilohms | 32.56 kilohms | About 32.1 kilohms | 28.674 kilohms |
| 25 degrees | 10.00 kilohms | 10.00 kilohms | 10.00 kilohms | 10.00 kilohms |
| 50 degrees | Not listed | 3.606 kilohms | 3.59 kilohms | Not listed |
| 60 degrees | 3.02 kilohms | Not listed | Not listed | Not listed |
The Beta Equation and the Steinhart-Hart Equation
The Beta equation is R equals R25 times e raised to B times one over T minus one over T25, with T in kelvin and T25 at 298.15 K, and working backwards, one over T equals one over T25 plus the natural log of R over R25 divided by B. The equation is exact only at the two calibration temperatures, with systematic error in between. Using B25/85 of 3977 K for the Vishay NTCLE100E3103, the Beta equation errs by plus or minus 0.4 degrees between about 15 and 100 degrees, but reports 0.76 degrees high at 0 degrees [A-S8][A-S3].
The Steinhart-Hart equation is more accurate: one over T equals A plus B times the natural log of R plus C times the cube of the natural log of R, with A, B, and C solved from three calibration points at least 10 degrees apart. A three-point fit for the same Vishay part errs by plus or minus 0.035 degrees between minus 20 and 120 degrees, about one twentieth of the Beta equation error. Vishay own four-term polynomial can press the error further down to 0.005 to 0.015 degrees [A-S3].
The practical meaning is this: the charging chip does not use the Beta equation, since it compares voltages against fixed thresholds, but when the fuel gauge chip reads temperature through its converter, the firmware converts with a resistance-temperature table or a Steinhart-Hart style model. Using the wrong B value or the wrong NTC model makes the converted temperature drift systematically away from the truth. Against the JEITA threshold at 0 degrees, the Beta equation error of reporting 0.76 degrees high at 0 degrees cannot be ignored [A-S35][A-S39][A-S3].
The Beta equation is exact only at the two calibration temperatures, with systematic error in between, while a Steinhart-Hart three-point fit errs by plus or minus 0.035 degrees between minus 20 and 120 degrees, about one twentieth of the Beta equation error [A-S3][A-S8].
Vishay own four-term polynomial can press the error further down to 0.005 to 0.015 degrees. When the fuel gauge chip reads temperature through its converter, the firmware converts with a resistance-temperature table or a Steinhart-Hart style model [A-S3][A-S35].
On tolerance stacking, an R25 tolerance of plus or minus 1 percent equals about plus or minus 0.25 degrees near 25 degrees, and the error from B value tolerance grows further away from 25 degrees [A-S8][A-S11].
| Model | Fit points | Error range [A-S3] |
|---|---|---|
| Beta equation | Two points | Plus or minus 0.4 degrees over 15 to 100 degrees, 0.76 degrees high at 0 degrees |
| Steinhart-Hart | Three points | Plus or minus 0.035 degrees over minus 20 to 120 degrees |
| Vishay four-term polynomial | Four terms | 0.005 to 0.015 degrees |
Self-Heating Error, Dissipation Constant, and Thermal Time Constant
An NTC warms itself when current passes through it, and the dissipation constant is the power needed to raise the part itself by one degree. A small glass bead runs near 1 milliwatt per kelvin, a coated radial part near 7 milliwatts per kelvin, the Vishay NTCLE100E3 at 7 milliwatts per kelvin with a thermal time constant of 15 seconds, the TDK B573 SMD near 3 milliwatts per kelvin with a time constant near 4 seconds, and an Ametherm probe at 3 milliwatts per degree with 6 seconds. The sensing circuit must use a low excitation current, or the reading shows the temperature after self-heating, not the battery temperature [A-S9][A-S10][A-S12][A-S14].
The thermal time constant means that after a step change in temperature, the NTC needs about one time constant to complete 63.2 percent of the change. A pack NTC stuck to a cell tab does not react at once, and the charging chip temperature sense comparator adds its own debounce time, so the two together make the true system reaction time to a sudden temperature change. The BQ24616 debounces threshold changes for 25 milliseconds and out-of-range temperature sense faults for 400 milliseconds [A-S9][A-S29].
Tolerance stacking must also be counted: an R25 tolerance of plus or minus 1 percent equals about plus or minus 0.25 degrees near 25 degrees, and the error from B value tolerance grows further away from 25 degrees. Even the TDK NTCG103JX103DT1, with R25 at plus or minus 0.5 percent, still shows a clear temperature reading gap between minimum and maximum parts, and only a Steinhart-Hart fit can press the model error below the part tolerance [A-S8][A-S11].
The sensing circuit must use a low excitation current, or the reading shows the temperature after self-heating, not the battery temperature. A pack NTC stuck to a cell tab does not react at once [A-S9][A-S10][A-S14].
Dissipation constant sets the size of self-heating error: a small glass bead runs near 1 milliwatt per kelvin, the TDK B573 near 3 milliwatts per kelvin, and a Vishay radial part near 7 milliwatts per kelvin. On thermal time constant, the TDK B573 runs about 4 seconds, an Ametherm probe 6 seconds, and a Vishay radial part 15 seconds [A-S10][A-S12][A-S14].
The thermal time constant means that after a step change in temperature, the NTC needs about one time constant to complete 63.2 percent of the change, while the charging chip sense comparator adds its own debounce time [A-S9][A-S29].
| Part | Dissipation constant | Thermal time constant |
|---|---|---|
| Small glass bead [A-S10] | About 1 milliwatt per kelvin | Not listed |
| Vishay NTCLE100E3 [A-S10] | 7 milliwatts per kelvin | 15 seconds |
| TDK B573 SMD [A-S12] | About 3 milliwatts per kelvin | About 4 seconds |
| Ametherm probe [A-S14] | 3 milliwatts per degree | 6 seconds |
NTC Packaging and Response Speed
The package of a sensor affects its response speed and reliability. The Amphenol Type FL is a thin-film NTC stuck to the battery pack surface, 1.0 millimetre thick, 10 kilohms plus or minus 3 percent, with B25/85 of 3936 K, made for battery pack temperature sensing. A glass packaged bead NTC resists environmental attack better, but its thermal contact is slower. Working temperature range depends on the package: a general SMD NTC runs about minus 40 to 125 degrees, a glass package can reach 300 degrees, the TDK B573 series runs minus 55 to 125 degrees, the Murata NCP18XH103F03RB runs minus 40 to 125 degrees, and the Semitec 103AT-2 and 103AT-3 run minus 50 to 110 degrees [B-S6][A-S12][A-S1][A-S5].
Newer pack-side fuel gauges carry several thermistor inputs, and the MAX17320 carries four thermistor inputs with plus or minus 1 degree accuracy, sampling one thermistor in turn every 1.4 seconds, so with all four enabled each sensor refreshes about every 5.6 seconds, with the temperature register taking the highest of the four sensors. That means one sensor reading high pulls the whole temperature judgement up. Patent records show a sensor can serve two duties: the same thermistor that watches cell temperature can also take part in overcharge and undercharge protection judgement, and the SMBus rules also allow a pack-outside temperature sensor as a backup beside the pack-inside thermistor [B-S14][B-S17].
A sensor sits in one of two physical places: inside the battery pack, stuck to a cell and carried out through the battery connector, which is the main subject of this guide, or on the mainboard near the charging chip, watching board temperature or acting as a backup. The two fail in similar ways, but the repair differs completely: a pack-inside sensor fault calls for replacing the whole battery pack, while a board sensor fault can be fixed with chip-level repair. No general source gives the exact board position of a mainboard NTC, since models place it in different spots, so this guide never claims a mainboard NTC always sits in one place [B-S14][B-S17][A-S35].
A sensor sits in one of two physical places: inside the battery pack, stuck to a cell and carried out through the battery connector, or on the mainboard near the charging chip, watching board temperature or acting as a backup. The two fail in similar ways, but the repair differs completely [B-S14][B-S17].
The Amphenol Type FL is a thin-film NTC stuck to the battery pack surface, 1.0 millimetre thick, 10 kilohms plus or minus 3 percent, with B25/85 of 3936 K, made for battery pack temperature sensing [B-S6][B-S14].
Patent records show a sensor can serve two duties: the same thermistor that watches cell temperature can also take part in overcharge and undercharge protection judgement, and the SMBus rules also allow a pack-outside temperature sensor as a backup [B-S17][B-S14].
See pricing for charges and diagnostics for the diagnostic route.
The TS Pin Divider Circuit: How a Charging Chip Sees Temperature
The central concept is that the charging chip never measures temperature directly; it measures the voltage on its temperature sense pin. The pin is biased through a resistor divider, with the NTC forming one arm of the divider, so when temperature moves, NTC resistance moves, pin voltage moves, and the charging chip compares that voltage with internal thresholds to judge which temperature band the battery sits in. A TI official reply puts it most plainly: the TS pin measures voltage, not temperature, and the voltage on the pin varies with the thermistor and the chosen bias resistors. That sentence is the key to this whole guide: anything that moves the pin voltage is read by the charging chip as a change in temperature [A-S22].
The typical divider structure, used by the BQ25600, BQ25882, and BQ25792 families, runs from the internal regulated output, called REGN, through a pull-up resistor RT1 to the temperature sense node, then through the NTC to ground, with a second resistor RT2 in parallel with the NTC to straighten the curve and narrow the pin voltage range. REGN is the reference voltage for the divider, and the temperature thresholds are expressed as a percentage of REGN rather than an absolute voltage, so when REGN itself drifts, every temperature threshold moves together. Measuring the sense pin means measuring REGN at the same time, or the percentage cannot be turned into a temperature [A-S22][A-S27][A-S17].
The divider resistors themselves are a fault point: a drifting pull-up, a drifting parallel resistor, a cracked joint, or water corrosion can all move the sense pin voltage while the NTC itself stays perfectly healthy. Measuring the sense pin voltage during repair cannot by itself prove the sensor is dead; the divider resistors and REGN must be measured first. Newer integrated charging chips also carry a converter reading for the sense pin, reporting the pin voltage as a percentage directly, so diagnosis can see at once what temperature the charging chip thinks the battery is at [A-S22][A-S33][A-S23].
A TI official reply puts it most plainly: the TS pin measures voltage, not temperature. Anything that moves the pin voltage is read by the charging chip as a change in temperature [A-S22][A-S17].
The sense pin voltage varies with the thermistor and the bias resistors, REGN is the divider reference voltage, and the temperature thresholds are expressed as a percentage of REGN, so REGN must be measured at the same time [A-S22][A-S17].
The divider resistors themselves are a fault point: a drifting pull-up, a drifting parallel resistor, a cracked joint, or water corrosion can all move the sense pin voltage while the NTC itself stays perfectly healthy [A-S22][A-S27].
| Node | Duty | What failure looks like |
|---|---|---|
| REGN [A-S17] | Divider reference voltage | Drift moves every threshold together |
| RT1 pull-up resistor [A-S22] | Bias the sense node | Drift moves the voltage |
| RT2 parallel resistor [A-S22] | Straighten the curve | Drift changes the voltage range |
| NTC [A-S22] | Turn temperature into resistance | Open reads cold, shorted reads hot |
Standard Divider Values: 103AT Plus 5.23 Kilohms Plus 30.9 Kilohms
The standard values come from the 103AT reference design: RT1 is a 5.23 kilohm pull-up and RT2 is a 30.9 kilohm parallel resistor, numbers taken from the BQ25600 and BQ25672 datasheets, while the BQ25672 discussion uses 30.1 kilohms, the same design in a different revision. With that resistor set plus the 103AT, the NTC reads 27.28 kilohms at 0 degrees, the parallel combination gives an equivalent resistance near 14.5 kilohms, and the sense pin voltage lands near 73.5 percent of REGN, right on the VT1 threshold [A-S22][A-S27].
The TI datasheet itself carries a documentation trap: the BQ25672 temperature sense calculation equations name VREF and VREGN inconsistently across revisions, and the official forum discussion confirms the datasheet equations are wrong, missing VREF or VREGN, while the TI official reply admits VREF equals VREGN and cancels out, yet the confused naming leads engineers to calculate a negative resistance. When quoting temperature sense divider maths, the checked combination of 103AT plus 5.23 kilohms plus 30.9 kilohms should be used, never a word-for-word copy of the datasheet equation [A-S27].
Another number set comes from the BQ24616: the temperature sense network uses the 103AT NTC with RT1 of 2.2 kilohms and RT2 of 6.8 kilohms as the worked example, and choosing T1 of 0 degrees and T5 of 60 degrees gives that resistor set. Divider resistor values are calculated from the NTC curve and the threshold temperatures, never picked at random. Different families use different divider values, so repair work must check the datasheet for that model, never carrying one set of numbers across to another design [B-S8][A-S29].
With the 103AT plus 5.23 kilohms plus 30.9 kilohms combination, the sense pin voltage lands near 73.5 percent of REGN at 0 degrees, right on the VT1 threshold [A-S22][A-S27].
The TI datasheet itself carries a documentation trap, with BQ25672 sense calculation equations naming VREF and VREGN inconsistently across revisions, while the official reply admits VREF equals VREGN and cancels out [A-S27][A-S22].
Another number set comes from the BQ24616: the temperature sense network uses the 103AT NTC with RT1 of 2.2 kilohms and RT2 of 6.8 kilohms as the worked example, and choosing T1 of 0 degrees and T5 of 60 degrees gives that resistor set [B-S8][A-S29].
| Design | RT1 pull-up | RT2 parallel | Reference NTC |
|---|---|---|---|
| BQ25600 / BQ25672 [A-S22] | 5.23 kilohms | 30.9 kilohms | 103AT |
| BQ25672 other revision [A-S27] | 5.23 kilohms | 30.1 kilohms | 103AT |
| BQ24616 [B-S8] | 2.2 kilohms | 6.8 kilohms | 103AT |
Other TS Structures: Current Source, 18 Kilohm Pull-Up, and BQ77915
A second structure belongs to the BQ2518x family: the temperature sense pin biases the NTC with an internal 38 microamp current source, the NTC runs straight from the pin to ground, and no external divider resistors are needed, with thresholds tuned for a 10 kilohm NTC with B25/85 of 3435 K. With that NTC, the default temperature window is cold 0 degrees, cool 10 degrees, warm 45 degrees, and hot 60 degrees. Hot or cold pauses charging, which resumes on its own once temperature returns inside the normal range, cool cuts charge current to one half or one fifth, and warm lowers the target charge voltage by 100 or 200 millivolts. This family watches the NTC only in charging and adapter modes, never watching battery temperature during discharge [A-S30].
A third structure sits on the BQ40Z50 and BQ28Z610 fuel gauge side: the TS1 to TS4 pins carry a built-in 18 kilohm typical linearisation pull-up, supporting a 10 kilohm NTC wired between the pin and VSS, with the converter reading through a multiplexer. The BQ28Z610 internal pull-up is rated 14.4 to 21.6 kilohms, drifting with temperature at minus 280 parts per million per degree typical. The pull-up resistor itself drifts with temperature, and that drift is one systematic error source in the gauge temperature reading [A-S35][A-S39].
A fourth structure belongs to the BQ77915 protection chip: the 103AT NTC runs between the sense pin and VSS, with a 10 kilohm resistor between VTB and the sense pin, and the temperature thresholds are stated in millivolts or as a percentage of VTB, so the real temperature threshold depends on the external parts chosen. The under-temperature charging threshold is 75.06 percent of VTB minimum, 77.22 percent typical, and 78.32 percent maximum. Real thresholds must be counted in millivolts, with the temperature figures only target values [A-S42][A-S41].
Four sense structures each bias differently: divider, 38 microamp current source, built-in 18 kilohm pull-up, and VTB divider. Repair work must first tell which structure it faces, never carrying one set of numbers across to another design [A-S30][A-S35][A-S42].
The third structure sits on the gauge side, with TS1 to TS4 carrying a built-in 18 kilohm typical linearisation pull-up supporting a 10 kilohm NTC, and the fourth structure is the BQ77915, with thresholds stated in millivolts or as a percentage of VTB [A-S35][A-S39][A-S42].
The BQ2518x family watches the NTC only in charging and adapter modes, never watching battery temperature during discharge. BQ77915 thresholds take the 103AT NTC between the sense pin and VSS with a 10 kilohm resistor between VTB and the sense pin as the baseline [A-S30][A-S42].
| Structure | Bias method | Chips it fits |
|---|---|---|
| Divider [A-S22] | REGN through RT1 and RT2 | BQ25600, BQ25882, BQ25792 |
| Current source [A-S30] | Internal 38 microamps | BQ2518x |
| Built-in pull-up [A-S35] | Built-in 18 kilohms | BQ40Z50, BQ28Z610 |
| VTB divider [A-S42] | 10 kilohms to VTB | BQ77915 |
Where JEITA Comes From and Why Charging Is Split Into Bands
The JEITA guidance comes from the Japan Electronics and Information Technology Industries Association and the Battery Association of Japan, which published lithium-ion charging safety guidance on 20 April 2007, aiming to stop high-current, high-voltage charging in certain cold and hot ranges. Any JEITA quotation should note that the source is the TI SLYT365 application note retelling of the guidance, never a direct quotation of the official JEITA document, since that official document itself could not be checked directly [A-S15].
The reason for splitting into bands is this: charging in the cold slows lithium-ion diffusion, so lithium deposits as metal on the anode, causing permanent capacity loss and safety risk, while charging in the heat leaves cathode material unstable, and overcharging speeds thermal runaway. Battery University gives independent confirmation: lithium-ion charges from 0 to 45 degrees and discharges from minus 20 to 60 degrees, fast charging is allowed from 5 to 45 degrees, current should be cut below 5 degrees, and charging below freezing is forbidden, with the best charging temperature from 10 to 30 degrees. Cold charging deposits metallic lithium on the anode even when the battery surface looks like it is charging normally, causing permanent performance and safety loss [A-S15][A-S16].
The TI JEITA article notes that single-cell handheld uses and laptop uses do not share the same thresholds, and laptop charger temperature thresholds are programmed by the user, not fixed values. Different brands and models can stop charging at different temperatures, so one model threshold must never be carried across to another model. That programmability means the same NTC and the same mainboard can behave completely differently under different embedded controller firmware settings [B-S14][A-S21].
JEITA guidance was published on 20 April 2007, aiming to stop high-current, high-voltage charging in certain cold and hot ranges. Cold charging deposits lithium as metal on the anode, while hot charging speeds thermal runaway [A-S15][A-S16].
Charging in the cold slows lithium-ion diffusion, so lithium deposits as metal on the anode, while charging in the heat leaves cathode material unstable, and overcharging speeds thermal runaway. That is why JEITA splits charging into bands [A-S15][A-S16].
The TI JEITA article notes that single-cell handheld uses and laptop uses do not share the same thresholds, and laptop charger temperature thresholds are programmed by the user, not fixed values [B-S14][A-S21].
| Temperature band | Danger | JEITA response |
|---|---|---|
| Cold charging [A-S16] | Lithium metal deposits on the anode | Cut current or forbid charging |
| Standard temperature [A-S15] | Lowest risk | Upper voltage and current |
| Hot charging [A-S15] | Cathode unstable, thermal runaway speeds up | Cut voltage or forbid charging |
The JEITA Temperature Bands: Laptop T1 to T5
For laptop use, the JEITA temperature bands, following TI SLYT365 for the laptop LiCoO2 system, are T1 near 0 degrees, T2 near 10 degrees, T3 near 45 degrees, and T4 near 60 degrees. The standard range T2 to T3, about 10 to 45 degrees, uses the upper charge voltage and current. The cold band T1 to T2 cuts current, and below T1 charging is forbidden. The hot band T3 to T4 cuts voltage, and above T4 charging is forbidden [A-S15].
The JEITA ceiling numbers are a laptop battery charge voltage ceiling of 4.25 volts and a charge current ceiling of 1 C, and when battery surface temperature climbs to 175 degrees with voltage at 4.3 volts, thermal runaway becomes possible. Those ceilings are safety design edges, not everyday charging targets. A battery temperature rise near 5 degrees during charging counts as normal, and when the rise passes 10 degrees at ordinary charging speed, the battery or charger should stop being used [A-S15][B-S18].
Different chip families define T4 and T5 with small differences: the BQ25882 family uses T5 for 60 degrees, the BQ24616 uses VT1 to VT5 for 0, 10, 45, 50, and 60 degrees, five thresholds, and the BQ25176J uses hot 55 degrees, warm 45 degrees, cool 10 degrees, and cold 0 degrees. Any threshold quotation must name the family it belongs to, never carrying five-threshold numbers across to a four-threshold design [A-S17][B-S8][B-S9].
Laptop bands run near T1 0 degrees, T2 10 degrees, T3 45 degrees, and T4 60 degrees, with the standard band using the upper charge voltage and current, the cold band cutting current, the hot band cutting voltage, and charging forbidden outside the range [A-S15][A-S16]. A Vishay application note notes that temperature protection in a battery management system must rest on accurate thermistor readings, since protection logic itself cannot correct a sensor error [B-S2].
The JEITA ceiling numbers are a laptop battery charge voltage ceiling of 4.25 volts and a charge current ceiling of 1 C, and when battery surface temperature climbs to 175 degrees with voltage at 4.3 volts, thermal runaway becomes possible [A-S15][B-S18].
Different chip families define T4 and T5 with small differences: the BQ25882 family uses T5 for 60 degrees, and the BQ24616 uses VT1 to VT5 for 0, 10, 45, 50, and 60 degrees, five thresholds [A-S17][B-S8].
| Temperature band | Approximate range | What the charging chip does |
|---|---|---|
| Below T1 [A-S15] | Below 0 degrees | Charging forbidden |
| T1 to T2 | 0 to 10 degrees | Current cut back |
| T2 to T3 [A-S15] | 10 to 45 degrees | Upper voltage and current |
| T3 to T4 | 45 to 60 degrees | Voltage cut back |
| Above T4 [A-S15] | Above 60 degrees | Charging forbidden |
How the BQ25882 and BQ25887 Put JEITA Into Practice
The BQ25882 and BQ25887 families put JEITA into practice with temperature sense pin voltage thresholds, expressed as a percentage of REGN. VT1, the T1 threshold at 0 degrees, is 73.25 percent, spanning 72.75 to 73.75 percent, and below that temperature charging pauses, with hysteresis VT1_HYS of 1.3 percent. VT2, the T2 threshold at 10 degrees, is 68.25 percent, and below that temperature charge current halves, with hysteresis of 1.3 percent [A-S17][A-S19].
VT3, the T3 threshold at 45 degrees, is 44.75 percent, and above that temperature charge voltage drops to 8.1 volts for two cells, with hysteresis of 1 percent. VT5, the T5 threshold at 60 degrees, is 34.375 percent, and above that temperature charging pauses, with hysteresis VT5_HYS of 1.35 percent. The chip own thermal regulation TREG is 120 degrees, thermal shutdown TSHUT rises at 150 degrees and falls at 120 degrees, and that is the charging chip own junction temperature protection, not battery temperature. The JEITA safety timer runs 12 hours [A-S17][A-S19].
Measured results from the BQ25887 evaluation board confirm that threshold set: the board uses a 103AT-2 NTC divider, and the sense pin voltage sits near 73.25 percent of REGN at 0 degrees and near 34.375 percent at 60 degrees, matching the datasheet thresholds exactly, while the TI official reply confirms the JEITA thresholds were designed around the 103AT-2 divider. The sense converter reading can also be used directly: a TS_ADC reading of 60 percent equals about 23.5 degrees, and 36 percent equals about 57 degrees, using a 10 kilohm Panasonic ERTJ1VG103FA NTC [A-S20][A-S33].
BQ25882 family JEITA thresholds are expressed as a percentage of REGN: VT1 73.25 percent, VT2 68.25 percent, VT3 44.75 percent, and VT5 34.375 percent [A-S17][A-S19][A-S20].
The BQ25887 evaluation board uses a 103AT-2 NTC divider, and the sense pin voltage sits near 73.25 percent of REGN at 0 degrees and near 34.375 percent at 60 degrees, matching the datasheet thresholds exactly [A-S20][A-S33].
The sense converter reading can be used directly: a TS_ADC reading of 60 percent equals about 23.5 degrees, and 36 percent equals about 57 degrees, using a 10 kilohm Panasonic ERTJ1VG103FA NTC [A-S33][A-S13].
| Threshold | Temperature | Percentage of REGN [A-S17] | Triggered action |
|---|---|---|---|
| VT1 | 0 degrees | 73.25 percent | Charging pauses |
| VT2 | 10 degrees | 68.25 percent | Current halved |
| VT3 | 45 degrees | 44.75 percent | Voltage drops to 8.1 volts |
| VT5 | 60 degrees | 34.375 percent | Charging pauses |
BQ25792 JEITA and TS_IGNORE
The BQ25792 family is the newer generation buck-boost charging chip for one to four cells. Before charging starts, the temperature sense pin voltage must sit inside the VT1 to VT5 thresholds, or the charger pauses and waits. In the cold band T1 to T2, JEITA_ISETC can be set to 20 percent, 40 percent, 100 percent, or pause, and in the hot band T3 to T5, JEITA_VSET can set the charge voltage offset to 0, 100, 200, 300, 400, 600, or 800 millivolts, or pause [A-S23].
TS_IGNORE is a register bit, and when it is set to 1, the charger ignores NTC monitoring and treats the temperature sense as always normal, while TS_STAT, the four states TS_COLD, COOL, WARM, and HOT, all report 000. That bit is a diagnosis trap: when the embedded controller or firmware wrongly sets TS_IGNORE, temperature protection effectively stops existing, and when TS_STAT reads all zeros, TS_IGNORE must be checked first, never concluding the NTC is healthy straight away. The BQ25792 also carries a TS_ADC register for reading the sense pin voltage percentage directly [A-S23].
The BQ25882 family JEITA programmable options are also worth remembering: the T1 to T2 band charge current can be set to 0, 20, 40, or 100 percent of the set value, the T3 to T5 band charge current to 40 or 100 percent, the T3 to T5 band charge voltage to pause, 8.0 volts, 8.3 volts, or the set value, and the T2 to T3 band uses the full set current and voltage, while a sense pin voltage outside the T1 to T5 range pauses charging until it returns inside. The BQ25886 is the fixed-threshold version: pause below T1, 20 percent current from T1 to T2, a fixed 8.0 volt charge voltage from T3 to T5, and pause above T5 [A-S18].
When TS_IGNORE on the BQ25792 is set to 1, the charger ignores NTC monitoring and TS_STAT all reports 000. On seeing TS_STAT all zeros, TS_IGNORE must be checked first, never concluding the NTC is healthy straight away [A-S23][A-S18].
BQ25882 family JEITA programmable options include T1 to T2 band current of 0, 20, 40, or 100 percent, and T3 to T5 band voltage of pause, 8.0 volts, 8.3 volts, or the set value [A-S18][A-S23].
The BQ25792 also carries a TS_ADC register for reading the sense pin voltage percentage directly. The BQ25886 is the fixed-threshold version: pause below T1, 20 percent current from T1 to T2, a fixed 8.0 volt charge voltage from T3 to T5, and pause above T5 [A-S23][A-S18].
| Setting | Cold band T1 to T2 | Hot band T3 to T5 |
|---|---|---|
| BQ25792 current [A-S23] | 20, 40, or 100 percent, or pause | Not listed |
| BQ25792 voltage [A-S23] | Not listed | Offset 0 to 800 millivolts, or pause |
| BQ25882 current [A-S18] | 0, 20, 40, or 100 percent | 40 or 100 percent |
| BQ25882 voltage [A-S18] | Not listed | Pause, 8.0 volts, 8.3 volts, or set value |
BQ25619 Programmable JEITA
The BQ25619 and BQ25618 families are single-cell chargers with I2C programmable JEITA. With T1 set to 0 degrees and T5 set to 60 degrees, T2 can be programmed to 5.5, 10 as default, 15, or 20 degrees, and T3 to 40, 45.5 as default, 50.5, or 54.5 degrees. Cold band charge current can be set to 0, 20 as default, 50, or 100 percent of charge current, and hot band charge voltage to 4.1 volts or held at the charge voltage, with charge current at 0, 20, 50, or 100 percent as default [A-S21].
That programmability means the same NTC and the same mainboard can behave completely differently under different embedded controller firmware settings. Repair judgement must rest on measured sense pin voltage plus register settings, never on what a model is supposed to do. The 103AT reference numbers also sit in this datasheet: RNTC,T1 is 27.28 kilohms at 0 degrees, and RNTC,T5 is 3.02 kilohms at 60 degrees [A-S21][A-S5].
Programmable T2 and T3 on the BQ25619 mean the thresholds are not written at the factory. Seeing charging cut back already at 15 degrees does not by itself prove sensor drift, since the firmware may have set T2 to 15 or 20 degrees. Likewise, seeing full-speed charging still at 50 degrees does not by itself prove protection has failed, since T3 may have been set to 54.5 degrees. Register readings and sense pin voltage must be read together [A-S21].
BQ25619 T2 and T3 can be programmed, so the thresholds are not written at the factory. Repair judgement must rest on measured sense pin voltage plus register settings [A-S21][A-S5].
BQ25619 T2 can be programmed to 5.5, 10, 15, or 20 degrees, and T3 to 40, 45.5, 50.5, or 54.5 degrees, with cold band current defaulting to 20 percent [A-S21][A-S5].
Seeing charging cut back already at 15 degrees does not by itself prove sensor drift, since the firmware may have set T2 to 15 or 20 degrees. Register readings and sense pin voltage must be read together [A-S21].
| Threshold | Programmable options [A-S21] | Default |
|---|---|---|
| T2 | 5.5, 10, 15, or 20 degrees | 10 degrees |
| T3 | 40, 45.5, 50.5, or 54.5 degrees | 45.5 degrees |
| Cold band current | 0, 20, 50, or 100 percent | 20 percent |
| Hot band current | 0, 20, 50, or 100 percent | 100 percent |
BQ25756 Family JEITA
The BQ25756 family is a wide-input buck-boost charging chip for one to fourteen cells. The temperature sense pin carries the JEITA profile, and assuming the pack uses a 103AT NTC, REGN feeds the sense pin through a divider, setting a T1 to T5 temperature window that stops charging when exceeded, with current cut in the T1 to T2 band and voltage cut in the T3 to T5 band, the exact ratios programmable through REG0x1B. The temperature window is the same set: T1 0 degrees, T2 10 degrees, T3 45 degrees, and T5 60 degrees [A-S24][A-S25].
The TI BQ25756 schematic checklist states plainly that the sense divider must run from REGN with a 103AT-2 10 kilohm thermistor, citing the datasheet JEITA section, and that sense traces should be routed away from switching noise sources. Switching noise coupled into the sense trace makes the pin voltage jump, so the charging chip can misjudge the temperature band and charging comes and goes [A-S26].
The BQ25756E is a revision in the same family, with the datasheet listing the sense pin JEITA profile and 16-bit converter temperature monitoring. A 16-bit converter can watch voltage, current, and power, and when its readings look wrong while a multimeter reads normal, the fault points at the converter or the reference voltage rather than the power stage. That distinction matters during diagnosis: converter readings and multimeter readings disagreeing with each other is itself a clue [A-S24].
The BQ25756 sense divider runs from REGN with a 103AT-2 10 kilohm NTC, and sense traces should be routed away from switching noise sources [A-S26][A-S24][A-S25].
The BQ25756 family is a wide-input buck-boost charging chip for one to fourteen cells, with the same temperature window of T1 0 degrees, T2 10 degrees, T3 45 degrees, and T5 60 degrees, and ratios programmable through REG0x1B [A-S24][A-S25].
The TI BQ25756 schematic checklist states plainly that the sense divider must run from REGN with a 103AT-2 10 kilohm thermistor, citing the datasheet JEITA section [A-S26][A-S25].
| Item | BQ25756 family [A-S24] |
|---|---|
| Cell count | One to fourteen cells |
| Temperature window | T1 0 degrees, T2 10 degrees, T3 45 degrees, T5 60 degrees |
| Divider supply | REGN |
| Reference NTC | 103AT-2 10 kilohms |
| Layout rule [A-S26] | Sense traces away from switching noise sources |
BQ2518x, BQ24610, and the BQ24770 With No TS Pin
The BQ2518x family biases with an internal 38 microamp current source, and with a 10 kilohm B3435 NTC the default window is cold 0 degrees, cool 10 degrees, warm 45 degrees, and hot 60 degrees. Hot or cold pauses charging, which resumes on its own once temperature returns inside the normal range, cool cuts charge current to one half or one fifth, and warm lowers the target charge voltage by 100 or 200 millivolts. This family watches the NTC only in charging and adapter modes, never watching battery temperature during discharge [A-S30].
The BQ24610 and BQ24616 families are standalone buck chargers from an older generation. The sense pin voltage must sit between VHTF and VLTF before charging can start, and in an official forum case the pin voltage was 97 percent of VREF while VLTF was 73.5 percent and VHTF was 37 percent, so charging paused, with the TI official reply stating plainly that the pin was biased wrongly. On debounce, T2, T3, and T4 threshold changes debounce for 25 milliseconds, and out-of-range sense faults debounce for 400 milliseconds [A-S28][A-S29].
Not every charging chip carries a temperature sense pin: the BQ24770 and BQ24773 have no TS pin at all and cannot watch battery temperature on their own, and the TI official reply says that kind of SMBus charging controller usually pairs with a fuel gauge that watches charge, charge voltage, charge current, battery temperature, and other parameters, with the host deciding how to control the BQ24770 from that data. That division of labour is the key to the four-layer temperature path: whether a chip without a sense pin has a temperature fault depends on the gauge side [A-S34].
The BQ2518x biases with a 38 microamp current source, the BQ24610 sense window runs 37 to 73.5 percent of VREF, and the BQ24770 carries no sense pin at all, with temperature coming from the gauge or embedded controller [A-S30][A-S28][A-S34]. The BQ25303J is a single-cell standalone charging chip that likewise supports JEITA temperature bands and NTC monitoring, showing JEITA is not limited to multi-cell machines [B-S10].
The BQ24616 sense network uses the 103AT NTC with RT1 of 2.2 kilohms and RT2 of 6.8 kilohms as the worked example, and on debounce, threshold changes take 25 milliseconds while out-of-range faults take 400 milliseconds [B-S8][A-S29].
The BQ24770 and BQ24773 have no temperature sense pin at all and cannot watch battery temperature on their own, and that kind of SMBus charging controller usually pairs with a fuel gauge that watches battery temperature and other parameters [A-S34][A-S35].
| Chip family | Temperature sense pin | Temperature window |
|---|---|---|
| BQ2518x [A-S30] | 38 microamp current source | Cold 0, cool 10, warm 45, hot 60 degrees |
| BQ24610 / BQ24616 [A-S28] | Divider, window 37 to 73.5 percent | 0, 10, 45, 50, 60 degrees |
| BQ24770 [A-S34] | No temperature sense pin | Relies on fuel gauge and embedded controller |
The Battery Pack Side: SBS Temperature() 0x08
The Smart Battery System, or SBS, is the standard interface between the battery pack and the host: the fuel gauge chip inside the pack reports charge, voltage, current, temperature, and more to the host over SMBus. The Temperature() register, 0x08, returns the internal temperature of the battery pack in units of 0.1 degrees kelvin, read as a word. Its typical working range is minus 20 to plus 75 degrees, defined pack by pack, with granularity of 0.5 degrees kelvin or better and accuracy of plus or minus 3 degrees kelvin. Its stated purpose is giving accurate cell temperatures for battery chargers and thermal management systems, so a charger can use temperature as a safety check [A-S43].
Two worked conversions make the units plain: 298.2 K equals 25.05 degrees, since 298.15 K equals 25 degrees, and a reading of 2731 in 0.1 kelvin units equals 273.1 K, or minus 0.05 degrees. Which temperature 0x08 returns is answered by a TI official forum note on the BQ30Z554-R1: 0x08 returns cell temperature, the average of all enabled temperature sensor readings, while 0x72, the Temperatures() register of 14 bytes, lists internal temperature, TS1 to TS4, cell temperature, and FET temperature separately. Protection logic can use the maximum rather than the average, depending on the temperature configuration setting [A-S44].
The internal temperature sensor of a fuel gauge chip and the external NTC are two different things: the internal sensor measures the chip itself, reflecting FET or board temperature, while the external NTC measures cell temperature. The battery temperature Windows reports comes from the external NTC converted by the gauge into cell temperature, not chip temperature, so a gap of a few degrees between the two is normal and the two must never be compared directly [A-S37][A-S39][A-S44].
SBS Temperature() 0x08 returns pack internal temperature in 0.1 degree kelvin units, with a typical range of minus 20 to plus 75 degrees and accuracy of plus or minus 3 degrees kelvin, giving accurate cell temperatures for chargers and thermal management systems [A-S43][A-S44].
Register 0x08 returns cell temperature, the average of all enabled temperature sensor readings, while 0x72 lists internal temperature, TS1 to TS4, cell temperature, and FET temperature separately. Protection logic can use the maximum rather than the average [A-S44][A-S37].
The battery temperature Windows reports comes from the external NTC converted by the gauge into cell temperature, not chip temperature, so a gap of a few degrees between the two is normal and the two must never be compared directly [A-S37][A-S39][A-S44].
Charges are listed under pricing, and the diagnostic route under diagnostics.
BQ40Z50 Fuel Gauge Temperature Inputs
The BQ40Z50 family is a one to four cell pack manager, fuel gauge and protection in one chip. It carries one internal temperature sensor plus four external temperature sensor inputs, TS1 to TS4, and all five can be enabled separately and set separately to measure cell temperature or FET temperature, with two configurable thermistor models, one for cell temperature and one for FET temperature. TS1 to TS4 can enable a built-in 18 kilohm typical linearisation pull-up, supporting a 10 kilohm external NTC such as the Mitsubishi BN35-3H103, the reference design uses four 10 kilohm thermistors, and any unused thermistor pin must be wired to VSS [A-S35][A-S36].
Need a laptop repair expert?
Free diagnosis · Transparent pricing · No fix, no fee · 180-day warranty
Temperature protection splits by charging and discharging, and by over-temperature and under-temperature: over-temperature charge protection, over-temperature discharge protection, under-temperature charge protection, under-temperature discharge protection, and over-temperature FET protection, with low-temperature protection using the lowest cell temperature sensor and high-temperature protection using the highest cell temperature sensor. Unused temperature sensors must be disabled by clearing the matching flag in the settings, or a floating sense pin will be read as an abnormal temperature [A-S37].
Open thermistor permanent failure is one of the permanent failure items of the BQ40Z50, listed in the technical reference manual. That means the gauge chip treats an open thermistor as a permanent failure to be recorded, not a one-off charging pause. A pack-inside NTC going open not only stops charging right now, it can also latch a permanent failure flag in the gauge, and clearing that failure record is needed after the NTC is replaced before charging can recover [A-S38][A-S35].
The BQ40Z50 carries one internal temperature sensor plus four external inputs, and TS1 to TS4 can enable a built-in 18 kilohm pull-up supporting a 10 kilohm NTC, while an open thermistor is one of its permanent failure items [A-S35][A-S37][A-S38].
BQ40Z50 temperature protection splits by charging and discharging, and by over-temperature and under-temperature, with low-temperature protection using the lowest cell temperature sensor and high-temperature protection using the highest. Unused temperature sensors must be disabled [A-S37][A-S35].
The gauge chip treats an open thermistor as a permanent failure to be recorded, not a one-off charging pause. Clearing that failure record is needed after the NTC is replaced before charging can recover [A-S38][A-S35].
| Input | Duty | Notes |
|---|---|---|
| TS1 to TS4 [A-S35] | External NTC, cell or FET temperature | Built-in 18 kilohm pull-up, supports 10 kilohm NTC |
| Internal sensor [A-S37] | Chip temperature itself | Not the same as cell temperature |
| Unused pins [A-S37] | Must be disabled and wired to VSS | Floating reads as abnormal temperature |
| Open fault [A-S38] | Permanent failure record | Record must be cleared after replacement |
BQ28Z610 and the BQ77915 Protection Chip
The BQ28Z610 family is a one to two cell fuel gauge plus protection chip. The TS1 input enables an internal 18 kilohm typical linearisation pull-up, supporting a 10 kilohm external NTC such as the Semitec 103AT-2, with the NTC wired between VSS and the TS1 pin and the converter reading through an input multiplexer. The internal temperature sensor voltage drifts at minus 2.0 millivolts per degree typical, and the internal pull-up drifts at minus 280 parts per million per degree typical [A-S39][A-S40].
The BQ77915 family is a three to five cell pack protection chip needing no microcontroller. On temperature protection, over-temperature charging sits at 45 or 50 degrees and over-temperature discharging at 65 or 70 degrees, with charging and discharging each carrying separate over-temperature and under-temperature thresholds, factory programmed with several configurations. Thresholds take the 103AT NTC between the sense pin and VSS with a 10 kilohm resistor between VTB and the sense pin as the baseline, and the under-temperature charging threshold is 75.06 percent of VTB minimum, 77.22 percent typical, and 78.32 percent maximum [A-S41][A-S42].
The gauge layer also carries its own temperature protection: the MAX17320 provides JEITA charging prescriptions, adjusting overvoltage thresholds and charging behaviour by temperature, and temperature-related overvoltage, overcharge, over-discharge, short-circuit, over-temperature, and under-temperature protection all rest on thermistor readings. When the sensor reading is wrong, the whole protection set follows it wrongly [B-S14][A-S37].
BQ28Z610 TS1 enables an internal 18 kilohm pull-up supporting the 103AT-2, and BQ77915 over-temperature charging sits at 45 or 50 degrees with over-temperature discharging at 65 or 70 degrees [A-S39][A-S41][A-S42].
BQ28Z610 internal temperature sensor voltage drifts at minus 2.0 millivolts per degree typical, and the internal pull-up drifts at minus 280 parts per million per degree typical. The MAX17320 provides JEITA charging prescriptions, adjusting overvoltage thresholds by temperature [A-S39][B-S14].
The gauge layer also carries its own temperature protection: the MAX17320 provides JEITA charging prescriptions, adjusting overvoltage thresholds and charging behaviour by temperature, and temperature-related protection all rests on thermistor readings [B-S14][A-S37].
| Chip | Temperature input | Protection thresholds |
|---|---|---|
| BQ28Z610 [A-S39] | TS1, built-in 18 kilohm pull-up | 103AT-2, NTC between VSS and TS1 |
| BQ77915 [A-S41] | 103AT NTC between TS and VSS | Over-temperature charge 45 or 50 degrees, over-temperature discharge 65 or 70 degrees |
| MAX17320 [B-S14] | Four thermistor inputs | JEITA charging prescriptions, adjusted by temperature |
The Four-Layer Temperature Path: Which Layer Reports What
The four-layer temperature path runs from the battery to the screen. Layer one: the pack-inside NTC, the cell temperature, runs through the fuel gauge chip sense pin, a BQ40Z50 or BQ28Z610, and out through SBS Temperature() 0x08. Layer two: the same NTC or another pack-inside NTC runs through the mainboard charging chip sense pin, a BQ25882 or BQ25792, and the JEITA comparator controls charging directly. Layer three: another NTC on the mainboard, near the charging chip or near the battery connector, runs through the embedded controller converter, judged by embedded controller firmware. Layer four: the embedded controller reports through ACPI, _BIF, _BIX, and _BST, through the Windows battery driver, to the taskbar, powercfg reports, HWiNFO, and other tools [A-S34][A-S43][A-S45].
The key point is that the charging chip sense pin and the fuel gauge chip sense pin are two separate paths, reading the same NTC or different NTC parts, with completely different judgement logic. The charging chip uses a voltage comparator to decide at once whether to charge, while the gauge uses a converter plus a firmware model to calculate a temperature in degrees, then reports it through SBS to the host. When either side says too hot or too cold, charging stops or slows, so diagnosis must measure the two apart, never looking at one side only [A-S34][A-S18][A-S23].
The practical meaning of layered judgement is this: when Windows reports a normal battery temperature, say 25 degrees, yet the charging chip stops charging, the fault more likely sits in the charging chip sense pin divider circuit or the charging chip itself, while when Windows reports an abnormal battery temperature, say minus 40 degrees or 85 degrees, yet the battery is actually at room temperature, the fault more likely sits in the pack-inside NTC or the gauge side. The two sides disagreeing is itself a diagnostic clue [A-S43][A-S47][A-S28].
The four-layer temperature path runs from the battery to the screen: gauge, charging chip, embedded controller, and Windows. The charging chip uses a voltage comparator to decide at once whether to charge, while the gauge uses a converter plus a firmware model to calculate a temperature in degrees [A-S34][A-S43][A-S45].
A charging chip without a sense pin relies completely on layers one and three: the gauge reports temperature to the embedded controller, which then orders the charging chip over SMBus to cut current or stop charging [A-S34][A-S43].
When Windows reports a normal battery temperature, say 25 degrees, yet the charging chip stops charging, the fault more likely sits in the charging chip sense pin divider circuit or the charging chip itself [A-S43][A-S47][A-S28].
| Layer | Path | What it reports |
|---|---|---|
| Layer one [A-S43] | Pack NTC to fuel gauge to SBS 0x08 | Cell temperature, in 0.1 degree kelvin units |
| Layer two [A-S18] | Pack NTC to charging chip TS pin | JEITA comparator deciding at once whether to charge |
| Layer three [A-S34] | Board NTC to embedded controller | Firmware judgement |
| Layer four [A-S45] | Embedded controller through ACPI to Windows | Battery temperature shown on screen |
Windows Readings: IOCTL, powercfg, and HWiNFO
On the Windows side, battery temperature is reported in 0.1 degree kelvin units through IOCTL_BATTERY_QUERY_INFORMATION, and the UEFI GetBatteryInformation call returns battery temperature in the same 0.1 degree kelvin units. That number finally comes from SBS Temperature() 0x08, the fuel gauge side, not the charging chip sense pin. The Windows battery driver only passes on the number the gauge reports; it measures no temperature itself [A-S45][A-S46][A-S43].
Windows powercfg /batteryreport is not a temperature monitoring tool: its standard fields cover capacity, usage history, and estimated runtime, with no battery temperature field, so temperature must be seen through a maker diagnostic tool, BIOS or UEFI, or a monitoring tool that plainly labels a battery sensor. CPU package, graphics hot spot, solid-state drive, voltage regulator, or mainboard temperatures must never be taken for battery temperature. The Smart Battery section of tools like HWiNFO can show design capacity, full charge capacity, wear, and charge or discharge state, and battery temperature only means something when the tool plainly labels a battery sensor [A-S47].
The reading technique is this: at room temperature near 25 degrees with the machine idle and cold, the battery temperature reading should sit near room temperature, and when a cold machine reads 60 degrees or minus 20 degrees or another extreme value, the sensor or its reading chain is almost certainly at fault. When two tools disagree, both read the same ACPI or SMBus source, so disagreement usually means one tool is reading a different field, and the BIOS or a cross-test should confirm the truth, never a single tool alone [B-S29][B-S27][B-S33].
Windows battery temperature finally comes from SBS Temperature() 0x08, the gauge side, not the charging chip sense pin. The powercfg report carries no standard temperature field, and processor temperature must never be taken for battery temperature [A-S45][A-S46][A-S47].
The reading technique is that at room temperature near 25 degrees with the machine idle and cold, the battery temperature reading should sit near room temperature, and when a cold machine reads 60 degrees or minus 20 degrees or another extreme value, the sensor or its reading chain is almost certainly at fault [B-S29][B-S27].
The Smart Battery section of tools like HWiNFO can show design capacity, full charge capacity, wear, and charge or discharge state, and battery temperature only means something when the tool plainly labels a battery sensor [A-S47][B-S27].
| Tool | What it shows | Limit |
|---|---|---|
| powercfg /batteryreport [A-S47] | Capacity, usage history, estimated runtime | No standard temperature field |
| HWiNFO Smart Battery [B-S27] | Design capacity, full charge capacity, wear | Battery temperature needs a plain label |
| BatteryInfoView [B-S29] | Temperature field is the pack sensor reading | Only reflects what the gauge reports |
| IOCTL query [A-S45] | Battery temperature, in 0.1 degree kelvin units | Finally comes from SBS 0x08 |
Maker Behaviour: Normal Protection on Lenovo, Dell, HP, and Getac
Maker behaviour confirms that stopping charging when temperature arrives is normal protection, not a fault. On Lenovo machines, a battery too hot cannot be charged, and the machine should be turned off and the battery left to cool to room temperature before charging. Lenovo mobile computers are generally designed for a working temperature near 5 to 35 degrees, with the best charging temperature near 10 to 35 degrees, and charging below 10 degrees runs slower. The Lenovo user guide states a charging temperature range of 10 to 35 degrees, no recharge until the level falls to 94 percent or below after a full charge, and conservation mode holding 75 to 80 percent [A-S48][A-S47][B-S39].
On Dell machines, the battery light flashing alternately green and amber means the battery is too hot to charge, and the battery and computer must be left to fall back to room temperature. On certain Dell G15 and G16 models, battery temperature above 50 degrees under heavy load triggers battery over-temperature protection. On HP machines, the charging system will not start while the computer runs hot, since adding more heat may damage parts, and battery or charging system overheat is normal behaviour, with charging resuming once the machine cools [A-S49][A-S47][A-S50].
The Getac S510 is an industrial machine with the fullest numbers: charging will not start when pack internal temperature sits below 0 degrees or above 50 degrees, charging stops above 60 degrees during charging, and high-temperature protection caps the maximum charge at 80 percent of total capacity. Opening a machine before the battery has cooled is a common waste. In a summer room without air conditioning, after a heavy load, or with a hot battery, a charging pause is normal JEITA protection that resumes after cooling [A-S55][A-S48][A-S50].
The Lenovo, Dell, and HP manuals all say stopping charging when temperature arrives is normal protection, resuming after cooling. Opening a machine before the battery has cooled is a common waste [A-S48][A-S49][A-S50][A-S55].
Getac S510 carries the fullest numbers: charging will not start when pack internal temperature sits below 0 degrees or above 50 degrees, charging stops above 60 degrees during charging, and high-temperature protection caps the maximum charge at 80 percent of total capacity [A-S55][A-S48].
On certain Dell G15 and G16 models, battery temperature above 50 degrees under heavy load triggers battery over-temperature protection. HP battery health management can cap charging at 80 percent [A-S47][B-S35].
| Brand | Normal protection behaviour | Recovery condition |
|---|---|---|
| Lenovo [A-S48] | Too hot to charge | Turn off, let the battery cool to room temperature |
| Dell [A-S49] | Green and amber flashing alternately | Let battery and computer fall back to room temperature |
| HP [A-S50] | Charging system will not start while hot | Resumes after cooling |
| Getac S510 [A-S55] | No charging below 0 degrees or above 50 degrees | Temperature returns inside the range |
Failure One: An Open NTC Reads as Extreme Cold
An open circuit means NTC resistance turns infinite, caused by a broken wire, a lifted solder joint, a snapped lead, or a connector pin pushed back inside. For the sense divider, an open NTC lets the pull-up resistor drag the sense node near REGN or VREF and VTSB, lifting the pin voltage above the top threshold. The BQ24610 official forum case is exactly this: the sense pin voltage was 97 percent of VREF, far above the VLTF threshold of 73.5 percent, the charging chip entered charge suspend mode, and the TI official reply said the pin was biased wrongly [A-S28].
The charging chip reads a high sense pin voltage as high NTC resistance, which means extremely low temperature. The symptom is no charging at all after plugging in the adapter, or only slow precharge, with the battery percentage never rising, while the adapter, the charging chip, and the battery voltage itself may all be normal. That symptom looks exactly like a dead charging chip, and it is the most common misdiagnosis. On the gauge side, the BQ40Z50 lists an open thermistor as a permanent failure to be recorded, not a one-off pause [A-S28][A-S38].
On the SBS temperature reading, an open NTC makes the gauge converter read a temperature down at the bottom of its range, say minus 40 degrees or lower, depending on the firmware clamp, and when Windows shows a battery temperature, it shows an unreasonably low number. That is the key clue for telling a pack-inside NTC open from a charging chip sense pin open: the first reports cold on both sides, while the second reports cold only on the charging chip side. Common open causes include pack connector mating cycles fatiguing the thin thermistor wires to breaking, pack NTC joints lifting from thermal expansion and contraction, mainboard sense divider joints cracking, and a dropped or knocked pack cracking the NTC body [A-S53][A-S54][A-S43].
When an NTC opens, resistance turns infinite, the sense pin voltage rises above the top threshold, and the charging chip reads the temperature as extremely low. That symptom looks exactly like a dead charging chip, and it is the most common misdiagnosis [A-S28][A-S38][A-S53].
Common open causes include pack connector mating cycles fatiguing the thin thermistor wires to breaking, pack NTC joints lifting from thermal expansion and contraction, mainboard sense divider joints cracking, and a dropped or knocked pack cracking the NTC body [A-S53][A-S54].
On the SBS temperature reading, an open NTC makes the gauge converter read a temperature down at the bottom of its range, and when Windows shows a battery temperature, it shows an unreasonably low number [A-S43][A-S44].
| Measurement point | Open reading | Normal reading |
|---|---|---|
| NTC body resistance [A-S1] | Infinite | About 10 kilohms at room temperature |
| TS pin voltage [A-S28] | Near REGN | Inside the threshold range |
| SBS temperature 0x08 [A-S43] | Extremely low, say minus 40 degrees | Near room temperature |
| Charging behaviour [A-S28] | No charging, or precharge only | Normal charging |
Failure Two: A Shorted NTC Reads as Extreme Heat
A short circuit means NTC resistance falls near 0 ohms, caused by a broken-down body, shorted leads, shorted connector pins, or water letting two wires conduct. For the sense divider, a shorted NTC drags the sense node near ground, dropping the pin voltage below the bottom threshold. The BQ24210 official forum discussion notes that a sense pin voltage below a certain percentage of VTSB is read as a hot battery, affecting charge current [A-S32].
The charging chip reads a low sense pin voltage as low NTC resistance, which means extremely high temperature. The symptom is no charging at all after plugging in the adapter, or charging that stops after a while, while the battery is plainly at room temperature yet the system says the battery is too hot. The Dell manual signal of green and amber flashing alternately meaning a battery too hot misreports in a shorted NTC case: the battery is not hot at all, yet the light says it is. On the gauge side, SBS Temperature() reports an unreasonable high temperature, say above 85 degrees, and when Windows shows it, the battery temperature stays high for a long time even though the machine only just started and the battery is cold [A-S32][A-S49][A-S43].
Telling a short from an open is direct: measure the sense pin voltage, which sits near REGN when open, meaning high, and near 0 volts when shorted, meaning low. Measure the NTC body resistance, which reads infinite when open and near 0 ohms when shorted. The two measurements together cannot be confused. A water short has a special character: Hong Kong humidity plus rain or a spilled drink wets the battery connector or the mainboard sense divider, a leakage path forms between pins, equal to a low-value resistor in parallel with the NTC, the pin voltage is dragged low, and the charging chip misjudges the battery as hot. That kind of fault may recover briefly once dry, giving on-and-off charging, but once corrosion starts, resistance keeps drifting [A-S53][A-S51].
When an NTC shorts, resistance falls near 0 ohms, the sense pin voltage drops below the bottom threshold, and the charging chip reads the temperature as extremely high. Measuring sense pin voltage plus NTC body resistance together never confuses an open with a short [A-S32][A-S49][A-S43].
A water short has a special character: Hong Kong humidity plus rain or a spilled drink wets the battery connector or the mainboard sense divider, a leakage path forms between pins, equal to a low-value resistor in parallel with the NTC [A-S53][A-S51].
On the gauge side, SBS Temperature() reports an unreasonable high temperature, say above 85 degrees, and when Windows shows it, the battery temperature stays high for a long time even though the machine only just started and the battery is cold [A-S32][A-S43].
| Measurement point | Shorted reading | Open reading | Normal reading |
|---|---|---|---|
| NTC body resistance [A-S1] | Near 0 ohms | Infinite | About 10 kilohms at room temperature |
| TS pin voltage [A-S32] | Near 0 volts | Near REGN | Inside the threshold range |
| SBS temperature 0x08 [A-S43] | Extremely high, say above 85 degrees | Extremely low | Near room temperature |
| Dell light [A-S49] | Green and amber flashing, wrongly reporting heat | May not flash | Normal |
Failure Three: Drift and Ageing
Drift means the NTC resistance-temperature curve slowly moves over time, not a sudden break or short, but a lie told further and further from the truth. The measured long-term stability number comes from the OCT Sensors technical note, which says their thermistors stored or run below 50 degrees drift typically less than 0.02 degrees per year, while stability depends heavily on environmental conditions such as humidity, excessive temperature, and thermal shock, and those effects should be kept as low as possible [A-S51].
Drift comes from ceramic material and metallisation layers ageing over time, faster when run near the rated temperature ceiling for long periods, while thermal shock, repeated fast cooling and heating, cracks the ceramic at a fine scale. The specification style for drift is that a reputable maker states long-term stability from accelerated ageing tests, in a form such as resistance shift below 0.2 percent after 1,000 hours at 100 degrees, while tolerance only describes accuracy at the moment the part leaves the factory, never long-term drift. In other words, an NTC that leaves the factory at plus or minus 1 percent can err far beyond plus or minus 1 percent after five years of use [A-S52].
Drift affects JEITA like this: suppose NTC resistance drifts 10 percent high, so the reading sits a few degrees low, and the charging chip mistakes a 45 degree battery for 40 degrees, keeps charging at full current, and loses high-temperature voltage cutback, while resistance drifting 10 percent low makes the chip mistake a 25 degree battery for above 30 degrees, entering the current-cutting band early, which shows up as charging growing slower and slower. Drift never stops charging outright, it only shifts the whole charging curve, and that is what makes a drift fault hardest to catch [A-S51][A-S18][A-S15].
Drift never stops charging outright, it only shifts the whole charging curve, and that is what makes a drift fault hardest to catch. Long-term stability depends heavily on humidity, excessive temperature, and thermal shock [A-S51][A-S52][A-S18].
The specification style for drift is that a reputable maker states long-term stability from accelerated ageing tests, in a form such as resistance shift below 0.2 percent after 1,000 hours at 100 degrees [A-S52][A-S51].
| Drift direction | Reading error | Charging chip mistake | Visible symptom |
|---|---|---|---|
| Resistance drifts high [A-S51] | Reading low by a few degrees | 45 degrees misread as 40 degrees | High-temperature voltage cutback lost |
| Resistance drifts low [A-S51] | Reading high by a few degrees | 25 degrees misread as above 30 degrees | Current cut early, charging grows slower |
| Long-term drift [A-S52] | Far beyond factory tolerance after five years | Thresholds shift as a whole | Whole charging curve shifts |
Failure Four: Corrosion, Connectors, and Flex Damage
Hong Kong humidity runs high, and rainy-season damp plus condensation in air-conditioned rooms easily corrodes the battery connector, the sense divider joints, and the NTC leads, so resistance drifts, the charging chip reads the wrong temperature, and charging comes and goes. NTC long-term stability itself suffers from humidity, and the maker technical note names humidity plainly as an environmental factor affecting stability. The temperature gap between an air-conditioned room and the humid outdoors leaves condensation inside the machine, and the mineral deposits left after it dries can cause tiny shorts or leakage current, disturbing the temperature reading chain [A-S51][A-S53][B-S49].
Repeated mating of the battery connector and bending of the mainboard battery flex can leave the two thin thermistor wires in intermittent contact, charging when moved one way and stopping when moved another. A Dell pack repair discussion confirms that once the two thin thermistor wires come off, the pack reports dead at once, and only a thermistor with the correct resistance value can bring it back, never a plain wire. Oxidised, pushed-back, or bent connector pins cause intermittent opens, and cleaning or replacing the connector can fix the fault without replacing the whole pack [A-S54][A-S53].
Commuting makes the trouble more visible: carrying a laptop on public transport every day shakes the battery connector for long periods, so the thin thermistor wires and pins fatigue and break sooner than on a machine left on a desk, and a dropped or knocked pack cracks the pack-inside NTC more readily. When a thermistor loses thermal contact with the battery, it reports a temperature below the real one, the charger runs on a wrong assumption, and it cannot switch charging correctly by the temperature thresholds. The sensor itself need not be broken; merely coming away from the cell surface is enough to defeat the protection [A-S54][B-S13][B-S33].
Hong Kong humidity runs high, and rainy-season damp plus condensation in air-conditioned rooms easily corrodes the battery connector, the sense divider joints, and the NTC leads, so resistance drifts, the charging chip reads the wrong temperature, and charging comes and goes [A-S51][A-S53][B-S49].
Oxidised, pushed-back, or bent connector pins cause intermittent opens, and cleaning or replacing the connector can fix the fault without replacing the whole pack. Commuting vibration makes the trouble more visible [A-S54][B-S33].
See pricing for charges and diagnostics for the diagnostic route.
Failure Five: Divider Resistor Drift and TS Pin Damage
The divider resistors themselves age and drift with damp: the pull-up, say 5.23 kilohms, and the parallel resistor, say 30.9 kilohms, both move in value, and when the pull-up grows, the sense pin voltage falls and the chip misjudges the battery as hot, while when the parallel resistor shrinks, the pin voltage falls the same way and the chip misjudges heat again. Replacing only the NTC without measuring the divider resistors lets the fault come back. The BQ28Z610 internal pull-up itself drifts with temperature at minus 280 parts per million per degree typical, one systematic error source in the gauge temperature reading [A-S22][A-S27][A-S39].
Static damage to the sense pin is a possibility on mechanism: plugging and unplugging the battery or adapter can discharge static into the charging chip sense input, breaking it down so the pin leaks or its input impedance changes, and a leaking pin drags the pin voltage low, so the chip misjudges heat. The TI layout guide carries general rules for input protection, but no standalone first-hand source for sense pin static damage was found in this round, so static is listed only as a mechanism possibility, with no exact static rating or failure rate stated [A-S27][A-S26].
Growing self-heating error is a knock-on problem: after an NTC ages, its dissipation constant changes, or the divider excitation current grows because resistor values moved, and self-heating error grows, pushing the reading further high. The sensing circuit must use a low excitation current, or the reading shows the temperature after self-heating. The measurement order should be NTC body resistance first, then divider resistors, then sense pin voltage and REGN, measuring the three apart before deciding whether the fault sits in the NTC, the resistors, or the charging chip pin [A-S9][A-S10][A-S22].
Divider resistors themselves age and drift with damp, and when the pull-up grows or the parallel resistor shrinks, the sense pin voltage falls and the chip misjudges heat. Replacing only the NTC without measuring the divider resistors lets the fault come back [A-S22][A-S27][A-S39].
Static damage to the sense pin is a possibility on mechanism, listed only as a mechanism possibility, with no exact static rating or failure rate stated [A-S27][A-S26].
| Fault point | Resistance change | TS pin voltage | Misjudged direction |
|---|---|---|---|
| Pull-up grows [A-S22] | RT1 rises | Falls | Misjudged as hot |
| Parallel resistor shrinks [A-S22] | RT2 falls | Falls | Misjudged as hot |
| TS pin leakage [A-S27] | Input impedance changes | Dragged low | Misjudged as hot |
| Self-heating grows [A-S9] | Excitation current rises | Reading high | Misjudged as hot |
Failure Six: Third-Party B Value Mismatch and Lost Thermal Contact
Third-party battery risk is a common local cause: a third-party pack may use an NTC with a different B value, say a B3950 in place of the 103AT B3435, or a less accurate NTC, and after fitting a third-party battery, charging behaves wrongly, slow, never full, or stopping and starting, so the first suspect should be an NTC model mismatch, not the mainboard. The 103AT and B3977 parts differ by more than 5 kilohms at 0 degrees, so fitting the wrong B value shifts the whole JEITA threshold set, and charging behaviour goes systematically wrong while the NTC itself measures normally [A-S5][A-S4][A-S54].
A Dell pack repair discussion gives a real mismatch case: the seller offered both a 10 kilohm 5 percent and a 100 kilohm 1 percent part, and picking wrongly means a tenfold resistance difference, while the discussion states plainly that it must be the correct sensor, never any part at hand. The consequence of mismatch is that a 100 kilohm NTC in place of a 10 kilohm NTC makes the system read far below the real temperature, the cold fault direction, so it may keep charging when truly overheating, while a 10 kilohm part in place of a 100 kilohm part reads far above the real temperature, the hot fault direction, refusing charging at once [A-S54][B-S1].
Lost thermal contact is another mismatch: when a sensor loses thermal contact with the battery, it reports below the real temperature, the charger runs on a wrong assumption, and it cannot switch charging correctly by the temperature thresholds. The special danger of that failure mode is that when the sensor reads low, the system may keep charging at full speed while the battery is truly overheating, raising thermal runaway risk. An older pack discussion also notes that sensor resistance should run about 10 to 25 kilohms and fall when held, which is the method of warming the pack by hand to find the sensor pins [B-S13][B-S46][B-S21].
A third-party battery may use an NTC with a different B value, and fitting the wrong B value shifts the whole JEITA threshold set, so charging behaviour goes systematically wrong while the NTC itself measures normally. Lost thermal contact also defeats protection [A-S5][A-S4][B-S13].
An older pack discussion also notes that sensor resistance should run about 10 to 25 kilohms and fall when held, which is the method of warming the pack by hand to find the sensor pins [B-S46][B-S21].
| Mismatch case | Reading direction | Consequence |
|---|---|---|
| B3950 in place of 103AT [A-S5] | Several degrees out in the hot band | Whole JEITA threshold set shifts |
| 100 kilohms in place of 10 kilohms [A-S54] | Reads far below the real temperature | Keeps charging when truly overheating |
| 10 kilohms in place of 100 kilohms [A-S54] | Reads far above the real temperature | Refuses charging at once |
| Lost thermal contact [B-S13] | Reads below the real temperature | Protection fails, thermal runaway risk rises |
Symptom One: Charging Stops at a Percentage
Charging stops at a percentage, say sixty, eighty, or ninety-five percent, and never moves. Rule out the maker charge limits first: Lenovo conservation mode holds charge within 75 to 80 percent, ASUS balanced mode stops at 80 percent and longest-life mode at 60 percent, HP battery health management can also cap at 80 percent, and Dell mostly-on-AC mode limits to 50 to 80 percent. The sensor suspect shows a stopping percentage that changes each time, or moves with room and machine temperature, while a limit setting stops at the same percentage every time [B-S38][B-S41][B-S33].
Lenovo documents also state that after a full charge, the level must fall to 94 percent or below before charging resumes, so stopping at 95 to 99 percent can be normal hysteresis. The ASUS design of not starting charging above 95 percent is also normal design, not a fault. The way to tell them apart is changing the limit setting temporarily to full capacity mode and watching whether the percentage climbs on, and when it still stops at a changing percentage, the sensor suspect grows [B-S39][B-S41].
Windows Smart Charging is another maker setting of the same kind: on supported devices it limits charging on its own, and a heart icon with a Fully Smart charged note means the charge limit is active, while Microsoft notes the switch differs by maker. On seeing the heart icon, limit settings should be checked first, never opening the machine at once. The largest difference between a sensor fault and a charge limit is that the first stops at a percentage that moves with temperature, while the second stops at the same figure every time [B-S23][B-S38][B-S41].
When charging stops at a percentage, rule out the maker charge limits first: Lenovo conservation mode 75 to 80 percent, ASUS balanced mode 80 percent and longest-life mode 60 percent, HP 80 percent, and Dell 50 to 80 percent [B-S38][B-S41][B-S33].
Lenovo documents also state that after a full charge, the level must fall to 94 percent or below before charging resumes, so stopping at 95 to 99 percent can be normal hysteresis [B-S39][B-S41].
| Case | Stopping percentage | How to tell |
|---|---|---|
| Lenovo conservation mode [B-S38] | 75 to 80 percent, same every time | Switch to full capacity mode and try again |
| ASUS balanced mode [B-S41] | 80 percent, same every time | Switch to full capacity mode and try again |
| ASUS longest-life mode [B-S41] | 60 percent, same every time | Switch to full capacity mode and try again |
| Sensor fault [A-S3] | Different each time, moves with temperature | Still stops at a changing percentage after changing the setting |
Symptom Two: Plugged In, Not Charging
At the Windows level, that message only means the adapter is connected yet the battery accepts no charge, with causes including charge limits, adapter recognition failure, driver trouble, battery failure, and temperature protection. The sensor suspect shows charging from a cold start, then a change to not charging once the machine warms up after a while, charging again after a night left to cool, or charging in an air-conditioned room yet not charging outdoors or in a stuffy hot place [B-S33][B-S35][A-S16].
On measured cases, Dedoimedo tested one Slimbook, a Linux machine, in practice: the battery stopped charging above 55 degrees and started slowing above about 50 degrees, and that is a single-model measured observation, not a general threshold, yet it proves the pattern of temperature leading and charging following. The same test also showed the system throttling the processor when battery temperature passed 75 degrees during discharge, the firmware behaviour of that model, not a general threshold, yet it shows a battery temperature reading can directly affect performance [B-S32].
The difference from a charging chip fault is that a charging chip fault usually stops charging without conditions, hot or cold alike, while a sensor fault usually tracks temperature and time. Noting when symptoms appear, whether plugging in brings any response, whether the machine only just finished a heavy load, and whether the room is a summer room without air conditioning helps testing narrow the direction faster. When the temperature reading is normal yet the battery still falls, the fault sits in the charging path or the adapter, not the sensor [B-S8][B-S32][B-S33].
For plugged in yet not charging, the sensor suspect shows charging when cold and stopping when hot, then charging again after cooling down. A charging chip fault usually stops charging without conditions, hot or cold alike [B-S33][B-S32][A-S16]
On measured cases, Dedoimedo tested one Slimbook in practice: the battery stopped charging above 55 degrees and started slowing above about 50 degrees, and that is a single-model measured observation, not a general threshold [B-S32].
| Symptom | Sensor suspect | Charging chip suspect |
|---|---|---|
| Charges cold, not hot [B-S32] | High, moves with temperature | Low |
| Never charges at any temperature [B-S8] | Low | High |
| Charges again after cooling [A-S16] | High | Low |
| Charges in air conditioning, not outdoors [B-S33] | High | Low |
Symptom Three: Battery Not Detected and False Overheat Shutdown
An open sensor can sometimes make the whole battery pack read as absent: the system reads no valid temperature signal, and together with SMBus communication failure, it reports no battery detected. The BIOS or UEFI is the most useful dividing line: when the BIOS also finds no battery, reinstalling Windows drivers will not help, and the fault sits at the pack, connector, or mainboard layer, while when the BIOS finds the battery yet Windows does not, the fault more likely sits at the driver or ACPI layer [A-S54][A-S53][B-S33].
Not detected and temperature fault are not the same thing: a temperature fault usually means the system knows the battery yet refuses to charge, while not detected means the system never knows a battery exists. The two have different measurement points and repair routes, and they must never be mixed. When nothing is detected, the measurement points sit in SMBus communication and power, while for a temperature fault they sit in the sense pin and sensor resistance [B-S33][A-S53].
On false overheat shutdown, a shorted sensor or a drifted divider resistor makes the system read far above the real temperature, triggering overheat protection that shuts the machine down or slows it, while the body feels only slightly warm, which is itself an important clue. The way to tell is comparing two temperature sources: battery temperature from HWiNFO64 Smart Battery or BatteryInfoView against processor or mainboard temperature, and when only battery temperature runs abnormally high while the rest stays normal, the sensor suspect is large, while when every temperature runs high together, cooling or true overheat is the larger suspect [B-S11][B-S13][B-S27][B-S29].
An open sensor can sometimes make the whole battery pack read as absent, and the BIOS is the most useful dividing line. In a false overheat shutdown, a body that feels only slightly warm is itself an important clue [A-S54][A-S53][B-S11]
Not detected and temperature fault are not the same thing: a temperature fault usually means the system knows the battery yet refuses to charge, while not detected means the system never knows a battery exists [B-S33][A-S53].
| Symptom | How to tell | Points at |
|---|---|---|
| BIOS finds no battery [B-S33] | Driver reinstall will not help | Pack, connector, or mainboard layer |
| BIOS finds it, Windows does not [B-S33] | Driver or ACPI layer | Driver, ACPI |
| Body slightly warm yet system says overheat [B-S11] | Compare battery and processor temperatures | Shorted sensor or drifted divider resistor |
| Every temperature high together [B-S27] | Compare several temperature sources | Cooling or true overheat |
Symptom Four: Very Slow Charging and Battery Still Falling While Plugged In
The JEITA cool and warm bands limit current by design: the BQ25176J cuts current to 20 percent in the cool band and to 50 percent in the warm band, so a sensor reading a few degrees high can hold the system in the current-cutting band for a long time, showing up as very slow charging. The way to tell is watching charge current move with temperature: when cooling restores normal charging speed, the sensor reading high is the suspect, while slowness at every temperature points at the charging chip, adapter wattage, or aged cells [B-S9][A-S3][A-S16].
Aged cells also slow charging, dragging a long tail through the constant-voltage stage, yet the charge current curve of an aged cell has nothing to do with temperature, while slow charging from a sensor fault tracks temperature. When charging runs very slowly, the sense pin voltage and the SBS temperature reading should be measured first, then charge current, never swapping the battery at once. A temperature reading high by a few degrees is already enough to trigger a JEITA threshold early [A-S16][B-S32][A-S33].
On the battery still falling while plugged in, the normal case is system load passing adapter supply, with the battery making up the difference, a dynamic power management behaviour, not a fault. The sensor suspect shows light load and enough adapter wattage, yet the battery still falls, while the battery temperature reading looks abnormal, which means the system thinks the battery is overheating and refuses charging, leaving the whole system load to the battery. The way to tell is confirming adapter wattage and delivery negotiation first, then looking at the battery temperature reading, and when the temperature reading is normal yet the battery still falls, the fault sits in the charging path or the adapter, not the sensor [B-S9][B-S32][B-S33][B-S35].
When charging runs very slowly, the sense pin voltage and the SBS temperature reading should be measured first, then charge current, never swapping the battery at once. A battery still falling while plugged in under light load points at the sensor refusing charging [B-S9][B-S32][B-S33]
Aged cells also slow charging, dragging a long tail through the constant-voltage stage, yet the charge current curve of an aged cell has nothing to do with temperature, while slow charging from a sensor fault tracks temperature [A-S16][B-S32].
The Eight-Layer Diagnosis at a Glance
The layering rule is reading numbers at the operating system layer first, then confirming at the BIOS or UEFI layer, then cross-testing, and only at the end opening the machine to measure board-level signals, never starting with disassembly. The eight layers run from shallow to deep: layer one, the Windows built-in battery report; layer two, Windows Device Manager; layer three, HWiNFO64 and BatteryInfoView live readings; layer four, maker tool readings; layer five, Linux readings; layer six, BIOS or UEFI confirmation; layer seven, multimeter measurement of the pack thermistor; layer eight, mainboard sense pin voltage measurement [B-S33][B-S22][B-S27].
The decisive cross-test is fitting a known good battery: testing with a known good maker battery of the same model is the most direct way to tell a pack fault from a mainboard fault. When charging recovers after the swap, the fault sits in the original pack, one of the cells, the sensor, or the pack-inside protection board, while when the fault stays after the swap, it sits on the mainboard, the connector, divider resistors, charging chip, embedded controller, or the adapter. The cross-test limit is that the substitute battery must be the same model with the same NTC value, since a substitute with the wrong NTC value makes the test result void and can even create a new false fault [B-S33][A-S53][A-S54].
Temperature comparison testing is also part of the layers: leave the pack at room temperature, about 25 degrees, for a while, then test again. When a cold room, say an air-conditioned room at 18 degrees, will not charge yet room temperature will, the fault may be a wrongly triggered JEITA cold band threshold, with NTC drift misreading 18 degrees as below 10 degrees, while when a hot place, say a summer room without air conditioning at 35 degrees, will not charge yet room temperature will, the fault may be a wrongly triggered hot band threshold. Change only one variable at a time [A-S15][A-S51][B-S32].
The eight-layer diagnosis runs from shallow to deep, never starting with disassembly. The decisive cross-test is fitting a known good battery of the same model, and the substitute battery must be the same model with the same NTC value [B-S33][A-S53][A-S54]
On temperature comparison testing, leave the pack at room temperature, about 25 degrees, for a while, then test again. Change only one variable at a time [A-S15][A-S51][B-S32].
| Layer | Tool | What it judges |
|---|---|---|
| Layer one [B-S22] | powercfg /batteryreport | Whether battery capacity already faded |
| Layer two [B-S24] | Device Manager | Whether the driver layer is healthy |
| Layer three [B-S27] | HWiNFO64, BatteryInfoView | Live battery temperature reading |
| Layer four [B-S39] | Maker tools | Battery state as the maker layer sees it |
| Layer five [B-S30] | upower, acpi | Linux layer reading for comparison |
| Layer six [B-S33] | BIOS / UEFI | Hardware layer reading past Windows |
| Layer seven [B-S21] | Multimeter | Pack sensor resistance |
| Layer eight [A-S22] | Multimeter, oscilloscope | Mainboard TS pin voltage |
Diagnosis Layers One to Three: Windows, Drivers, and Live Readings
Layer one is the Windows built-in battery report: powercfg /batteryreport builds an HTML report, and comparing design capacity with full charge capacity judges whether the battery itself already faded, while the report also carries capacity history and battery usage records. The limit is that the report only reflects what the gauge reports, with no temperature reading, so a normal report cannot prove the sensor healthy, and an abnormal report cannot by itself prove the sensor dead. In practice, a full charge capacity far below design capacity makes aged cells the larger suspect, while normal capacity with abnormal charging behaviour makes the sensor or the charging path the larger suspect [B-S22].
Layer two is Windows Device Manager: open the battery section and check the Microsoft ACPI-Compliant Control Method Battery and Microsoft AC Adapter for yellow warning marks, and uninstalling then scanning for hardware changes can let Windows rebuild the battery state receiving path. Note that Microsoft Q&A warns the Surface Pro X battery driver should not be uninstalled, since restoring it may need a full system reset, and that warning targets that model only. Driver reinstall only fixes the Windows receiving layer, and when the BIOS also finds no battery or the temperature reading looks abnormal, driver reinstall will not help [B-S24][B-S25].
Layer three is HWiNFO64 and BatteryInfoView live readings: the HWiNFO64 Sensors mode carries a Smart Battery section, and comparing Designed Capacity with Full Charged Capacity gives the wear percentage at once, while sensor data can be logged to CSV to track temperature over time. The Temperature field BatteryInfoView shows is the battery temperature the pack sensor reports, and extreme readings can trigger throttling or charging limits. The NirSoft original text lists the fields the tool shows, including battery name, manufacturer, serial number, manufacture date, power state, capacity, voltage, and charge or discharge rate [B-S27][B-S29][B-S28].
Layer one powercfg reporting only reflects what the gauge reports, with no temperature reading, layer two driver reinstall only fixes the Windows receiving layer, and layer three live readings must use a field that plainly labels a battery sensor [B-S22][B-S24][B-S27]. The Linux kernel also carries NCP thermistor compensation tables converting resistance to temperature, and its reading chain depends on the same sensor data as Windows [B-S16].
Driver reinstall only fixes the Windows receiving layer, and when the BIOS also finds no battery or the temperature reading looks abnormal, driver reinstall will not help [B-S24][B-S25][B-S33].
| Layer | Check point | Passing does not prove |
|---|---|---|
| Layer one [B-S22] | Full charge capacity against design capacity | It does not prove the sensor healthy |
| Layer two [B-S24] | Battery driver yellow warning marks | It does not prove the hardware layer healthy |
| Layer three [B-S27] | Live battery temperature near room temperature | One tool reading needs confirming |
Diagnosis Layers Four to Six: Maker Tools, Linux, and BIOS
Layer four is maker tool readings: Lenovo Vantage can run a battery gauge reset and health check, and the Lenovo user guide states plainly that battery temperature can be checked in Lenovo Vantage or Lenovo PC Manager. HP Support Assistant, under My Dashboard, Battery, and Run battery check, can run a battery health check, while HP PC Hardware Diagnostics UEFI, entered by pressing Esc then F2 at startup and choosing Component Tests and Battery, finishes a battery test in about 2 minutes, and passing does not prove the charging path healthy. MyASUS, under System Diagnosis, Diagnostic Tool, and Battery problems, can diagnose battery trouble, and Battery Care Mode also sits in MyASUS. Dell SupportAssist, MyDell, and Dell Power Manager can scan battery hardware trouble, showing battery health and charging mode settings, and Dell Power Manager can set custom start and stop charge percentages [B-S39][B-S40][B-S35][B-S36][B-S41][B-S33].
Passing a maker tool test does not mean the sensor is healthy: maker battery tests mainly measure capacity and charge or discharge, and an intermittent sensor fault may never be caught. The Lenovo Vantage Battery Gauge Reset can correct percentage readings, yet it cannot rebuild faded cells or add real capacity, and when readings stay abnormal after a reset, board-level measurement should follow [B-S35][B-S36][B-S26][B-S40].
Layer five is Linux readings, for dual-boot or Linux machines: upower -i /org/freedesktop/UPower/devices/battery_BAT0 shows battery state, energy, voltage, temperature when the firmware provides it, and more, upower -e lists device paths first, and upower --monitor watches power events live. acpi -V shows charge state, percentage, temperature, and thermal zone readings in one line, while acpi -t shows temperature only. Note that the Linux temperature field comes from the same ACPI or embedded controller data, not an independent measurement, so a Windows reading abnormal with a Linux reading normal points at the Windows driver layer, while both systems abnormal points at hardware [B-S30][B-S31][B-S32]. Layer six is BIOS or UEFI confirmation: Dell enters BIOS by pressing F2 repeatedly at startup, showing battery health and adapter state under Power or Battery, and when adapter state shows Unknown, the battery may not charge, with the cause mostly in the adapter, DC-in interface, or mainboard charging circuit. HP enters UEFI diagnostics by pressing Esc then F2, choosing Component Tests, Power, and Battery for a battery test, and a failed test produces a 24-digit Failure ID. Some Lenovo models enter UEFI Diagnostics with F10 or F11 for a battery test, and the charging test needs the adapter connected with the battery at 95 percent or below. The BIOS layer matters because BIOS readings bypass Windows and reflect the battery state the embedded controller or firmware sees directly, so an abnormal BIOS temperature or health reading points at the hardware layer [B-S33][B-S36][B-S40].
Passing a maker tool test does not mean the sensor is healthy, Linux readings come from the same ACPI data rather than an independent measurement, and BIOS readings bypass Windows and reflect the hardware layer state directly [B-S35][B-S30][B-S33][B-S36]
Layer six is BIOS or UEFI confirmation: Dell enters BIOS by pressing F2 repeatedly at startup, HP enters UEFI diagnostics by pressing Esc then F2, and some Lenovo models enter UEFI Diagnostics with F10 or F11 [B-S33][B-S36][B-S40].
| Layer | Tool | Key numbers |
|---|---|---|
| Layer four [B-S36] | HP UEFI battery test | About 2 minutes, a failed test gives a 24-digit Failure ID |
| Layer five [B-S30] | upower, acpi | Same ACPI data, not an independent measurement |
| Layer six [B-S33] | Dell BIOS F2 | Adapter state Unknown points at adapter or charging circuit |
Diagnosis Layer Seven: Measuring the Pack Sensor With a Multimeter
Layer seven is measuring the pack thermistor with a multimeter, measuring connector pins only, and never opening the battery pack. The method is measuring the two sensor pins on the battery connector with the resistance range, and the most common thermistor is a 10 kilohm NTC reading about 10 kilohms at room temperature near 25 degrees. An All About Circuits discussion also notes that reading 10 kilohms at 25 degrees means a 10 kilohm type [B-S21][A-S54].
The way to find the pins is trying pin pairs with the resistance range, since sensor pin resistance moves with temperature, and warming the pack by hand should make resistance fall slightly, the identification method BU-911 suggests, while an older pack discussion also notes sensor resistance should run about 10 to 25 kilohms and fall when held. On expected readings at room temperature near 25 degrees, a normal 10 kilohm NTC reads about 8 to 12 kilohms, depending on tolerance and real room temperature, an open reads infinite, shown as OL, and a short reads near 0 ohms, while a 100 kilohm NTC reads about 100 kilohms at 25 degrees. When the original machine uses 10 kilohms yet the reading is 100 kilohms, the sensor was replaced wrongly or a third-party battery uses the wrong value [B-S21][B-S46][B-S1][A-S54].
The measurement conditions are that the pack must be removed from the machine with no adapter connected, and discharged below 25 percent before measuring, the iFixit safety guidance, so stored energy stays low when something goes wrong by accident. The safety red line is measuring connector pins only, never opening the pack shell, never measuring the cells themselves, and never piercing or squeezing a cell, while a swollen battery must never be measured and should be taken out of use at once. The room temperature at the time must be stated when measuring, never saying a reading other than exactly 10.00 kilohms means a dead part, since BU-911 gives 10 kilohms at 20 degrees while the Murata datasheet gives 10 kilohms at 25 degrees, and the same 10 kilohm NTC reads slightly above 10 kilohms at 20 degrees [B-S42][B-S21][B-S34][A-S53].
Layer seven measures connector pins only, never opening the battery pack. A normal 10 kilohm NTC reads about 8 to 12 kilohms at room temperature near 25 degrees, an open reads infinite, and a short reads near 0 ohms [B-S21][A-S54][B-S42]
The measurement conditions are that the pack must be removed from the machine with no adapter connected, and discharged below 25 percent before measuring, the iFixit safety guidance [B-S42][B-S21].
| Reading (room temperature near 25 degrees) | Judgement |
|---|---|
| About 8 to 12 kilohms [B-S21] | Normal 10 kilohm NTC |
| Infinite, OL [A-S54] | Open circuit |
| Near 0 ohms [A-S54] | Short circuit |
| About 100 kilohms [A-S54] | Wrong sensor fitted or third-party wrong value |
Diagnosis Layer Eight: Mainboard TS Pin Voltage
Layer eight is mainboard temperature sense pin voltage measurement, board-level work that must be done by a qualified repair worker. The method is that the charging chip sense pin runs through divider resistors to the NTC, so measuring the pin voltage to ground tells whether the sensor, the connector, or the divider resistors are at fault. On reference thresholds, the LT3650 design stops charging above 1.36 volts on the NTC pin, meaning below 0 degrees, and below 0.29 volts, meaning above 40 degrees. Those numbers fit the LT3650 design only and must never be carried across to BQ models [B-S8][B-S11].
The BQ24616 sense thresholds are counted in percentages: VT1 is about 70.8 percent of the reference voltage typical, and when the measured sense pin voltage of 2.33 volts sits near VT1, the charger pauses again and again. A TI official forum discussion confirms behaviour near a threshold is not an instant switch: the BQ24616 temperature check carries a debounce time, confirming a sense fault only about 400 milliseconds after leaving the range, and when the sense pin voltage sits near the VT1 threshold, say 2.33 volts against a typical 2.3364 volts, the charger enters and leaves temperature pause again and again [A-S29].
The reading logic is that a sense pin voltage equal to the reference voltage, the top of the divider, means the sensor is open or the connector is broken, a sense pin voltage near 0 volts means the sensor is shorted or a divider resistor is shorted, and a sense pin voltage moving sensibly with temperature while charging still stops means the fault may sit in the charging chip or the embedded controller, not the sensor. On an illustrative calculation, with a 3.3 volt reference and a 10 kilohm fixed resistor in series with a 10 kilohm NTC, the sense pin voltage is about 1.65 volts at 25 degrees, falling as temperature rises and NTC resistance falls, and rising as temperature falls, a sense of direction shared by every divider design, while real numbers must be calculated from that model reference voltage and resistor values. Board-level measurement is triggered when a known good battery still will not charge, software readings look abnormal yet the pack measures normally, or divider resistors or the connector are suspected [B-S8][B-S11][B-S3][B-S15][B-S33][B-S48].
Layer eight measures the sense pin voltage to ground: equal to the reference voltage means open or broken, near 0 volts means shorted, and moving sensibly with temperature while charging still stops means the fault may sit in the charging chip or the embedded controller [B-S8][B-S11][A-S29]
On an illustrative calculation, with a 3.3 volt reference and a 10 kilohm fixed resistor in series with a 10 kilohm NTC, the sense pin voltage is about 1.65 volts at 25 degrees, a sense of direction shared by every divider design [B-S3][B-S15].
| TS pin voltage | Judgement |
|---|---|
| Equals the reference voltage [B-S8] | Sensor open or connector broken |
| Near 0 volts [B-S11] | Sensor shorted or divider resistor shorted |
| Moves sensibly with temperature yet still stops charging [B-S8] | Fault may sit in the charging chip or embedded controller |
| Jumping again and again near the VT1 threshold [A-S29] | Threshold edge, debounce has not confirmed a fault |
Measurement Points and Judgement Standards at a Glance
On NTC body resistance, measured with the pack disconnected at room temperature near 25 degrees, the reading should be about 10 kilohms, with 103, 103AT, and XH103 all at 10.0 kilohms. When the measuring temperature is not 25 degrees, the resistance-temperature table must be used to convert, say 27.28 kilohms for the 103AT and 32.56 kilohms for the B3977 part at 0 degrees. Infinite means open, near 0 ohms means shorted, and a clear move away from the table, say 15 kilohms at 25 degrees, means drift or a wrong model [A-S1][A-S5][A-S4].
On sense pin voltage, with the adapter plugged in and the battery fitted, the reading should sit inside the JEITA threshold range. For the BQ25882 and BQ25887, the sense pin voltage should sit between 34.375 and 73.25 percent of REGN, and leaving that range pauses charging. For the BQ24610, the sense pin voltage should sit between 37 percent of VREF, the VHTF threshold, and 73.5 percent, the VLTF threshold. On the REGN pin, the sense thresholds are expressed as a percentage of REGN, so REGN must be measured before the sense pin, or the percentage means nothing, and when REGN shows no voltage, the charging chip never started, pointing at supply or the chip itself [A-S17][A-S19][A-S28].
On divider resistors, the pull-up, say 5.23 kilohms, and the parallel resistor, say 30.9 kilohms, must be measured one by one against the datasheet numbers, and any move beyond tolerance means replacement. On the sense converter register, models with a converter such as the BQ25882 and BQ25792 can read the sense pin voltage percentage directly, with 60 percent equal to about 23.5 degrees and 36 percent equal to about 57 degrees using a 10 kilohm Panasonic ERTJ1VG103FA. That reading is the temperature the charging chip thinks it sees, not the true battery temperature. On SBS Temperature() 0x08, read through the embedded controller, HWiNFO, BatteryInfoView, and similar tools, the reading should sit near room temperature, say near 25 degrees, and when it reports an extreme value such as minus 40 degrees or 85 degrees while the battery is actually at room temperature, the fault sits in the pack-inside NTC or the gauge side [A-S22][A-S27][A-S33][A-S43][A-S47].
The measurement point checklist starts with REGN, then sense pin voltage, then divider resistors, then NTC body resistance. The sense converter reading is the temperature the charging chip thinks it sees, not the true battery temperature [A-S17][A-S22][A-S33][A-S43]
On divider resistors, the pull-up and the parallel resistor must be measured one by one against the datasheet numbers, and any move beyond tolerance means replacement [A-S22][A-S27][A-S33].
| Measurement point | Normal value | What an abnormal reading points at |
|---|---|---|
| NTC body resistance, 25 degrees [A-S1] | About 10 kilohms | Infinite means open, near 0 ohms means shorted |
| TS pin voltage, BQ25882 [A-S17] | 34.375 to 73.25 percent of REGN | Leaving the range pauses charging |
| TS pin voltage, BQ24610 [A-S28] | 37 to 73.5 percent of VREF | Leaving the range pauses charging |
| REGN [A-S17] | Internal regulated output normal | No voltage means the chip never started |
| Divider resistors [A-S22] | 5.23 and 30.9 kilohms | Drift beyond tolerance means replacement |
| TS_ADC [A-S33] | 60 percent near 23.5 degrees, 36 percent near 57 degrees | Reading is the temperature the chip thinks it sees |
| SBS 0x08 [A-S43] | Near room temperature | Extreme value points at pack NTC or gauge |
Misdiagnoses Part One: Open, Shorted, and Drifted Sensors Mimicking Other Faults
Misdiagnosis one is treating an open NTC as a dead charging chip. The symptoms look exactly the same, no charging with the adapter plugged in, yet measuring the sense pin voltage shows near REGN and measuring the NTC shows infinite, so swapping the charging chip helps nothing, and replacing the NTC or fixing the divider circuit is the right fix. Misdiagnosis two is treating a shorted NTC as an overheating battery. The system says the battery is too hot and the Dell light says it is too hot, yet the battery is actually at room temperature, and measuring the sense pin voltage shows near 0 volts while measuring the NTC shows near 0 ohms [A-S28][A-S53][A-S32][A-S49].
Misdiagnosis three is treating a drifted NTC as a weak charging chip. Charging grows slower and slower and never fills, yet the other charging chip measurement points, including ACOK, PHASE, and charge current, all read normally, and the trouble is NTC drift holding the charging chip in the JEITA current-cutting band for long periods. Misdiagnosis four is treating a gauge chip temperature misreport as a dead charging chip. Windows reports an abnormal battery temperature, yet the charging chip sense pin voltage reads normally, so the fault sits in the pack-inside NTC or the gauge chip, not the charging chip [A-S18][A-S51][A-S43][A-S44].
Misdiagnosis five is treating a sensor fault as an aged battery. The battery percentage and capacity look normal, yet charging comes and goes, and after fitting a new battery the fault stays, when the real cause is a board divider resistor or connector fault, not aged cells. Misdiagnosis six is treating an aged battery as a sensor fault. Full charge capacity far below design capacity, clearly shorter runtime, and a charging curve dragging a long tail through the constant-voltage stage come from rising cell internal resistance, and swapping the sensor or any part other than the pack will never bring capacity back [B-S33][B-S48][A-S16][B-S22].
Misdiagnoses one to six share unfinished layered checks: open, shorted, drifted, gauge misreport, and aged battery can all mimic a dead charging chip or a dead battery [A-S28][A-S32][A-S51][A-S43][B-S33][B-S22]
Misdiagnosis four is treating a gauge chip temperature misreport as a dead charging chip. Windows reports an abnormal battery temperature, yet the charging chip sense pin voltage reads normally, so the fault sits in the pack-inside NTC or the gauge chip [A-S43][A-S44].
| Misdiagnosis | Real cause | Measurement clue |
|---|---|---|
| Open treated as dead charging chip [A-S28] | NTC open | TS pin near REGN, NTC infinite |
| Shorted treated as overheating battery [A-S32] | NTC shorted | TS pin near 0 volts, NTC near 0 ohms |
| Drift treated as weak charging [A-S51] | NTC drift | Other points normal, long stay in current-cutting band |
| Gauge misreport treated as dead charging chip [A-S43] | Pack NTC or gauge | TS pin voltage normal, SBS temperature abnormal |
| Sensor fault treated as aged battery [B-S33] | Divider resistor or connector | New battery leaves the fault unchanged |
| Aged battery treated as sensor fault [B-S22] | Cell internal resistance rising | Full charge capacity far below design capacity |
Misdiagnoses Part Two: Firmware Limits and the EC Layer
Misdiagnosis seven is treating a firmware or embedded controller charge limit as a sensor fault. Lenovo conservation mode at 75 to 80 percent, ASUS at 60 or 80 percent, Dell at 50 to 80 percent, HP with an 80 percent cap, the 95 percent recharge hysteresis, and Windows Smart Charging, the heart icon with Fully Smart charged, are all maker settings that should be checked before anything else. Misdiagnosis eight is treating a sensor fault as a firmware problem. A BIOS update can fix communication trouble between the embedded controller and the charging chip, yet it cannot fix an already open sensor, a drifted divider resistor, or an oxidised connector, so when the fault stays after an update, board-level measurement should follow [B-S23][B-S33][B-S38][B-S39][B-S41].
Misdiagnosis nine is treating an embedded controller fault as a sensor fault. The embedded controller reads temperature and writes charge parameters to the charging chip, and when the controller freezes or its firmware settings go wrong, charging can pause while the sensor and divider resistors measure completely normally. The way to tell is a normal sense pin voltage reading with charging behaviour still abnormal. Misdiagnosis ten is treating divider resistor drift as a dead sensor. The sensor itself measures normally, about 10 kilohms at 25 degrees, yet the sense pin voltage looks abnormal, so the fault sits in a fixed divider resistor on the mainboard drifting in value, and replacing the pack will not fix it, since board-level repair is needed [B-S8][A-S29][B-S48][A-S22].
Misdiagnosis eleven is treating a charging chip without a sense pin as one that has one. The BQ24770 carries no temperature sense pin at all and relies completely on the fuel gauge or embedded controller for temperature, so when embedded controller firmware or SBS communication goes wrong, the charging chip is ordered to stop charging, yet the chip itself is healthy. Misdiagnosis twelve is treating normal JEITA protection as a fault. In a summer room without air conditioning, after a heavy load, or with a hot battery, a charging pause is normal protection that resumes after cooling, and the Lenovo, Dell, and HP manuals all say so. Opening a machine before the battery has cooled is a common waste [A-S34][A-S48][A-S49][A-S50].
Misdiagnoses seven to twelve share the firmware and embedded controller layer: charge limits, BIOS updates, a frozen embedded controller, drifted divider resistors, a chip with no sense pin, and normal JEITA protection [B-S23][A-S34][A-S22][A-S48]
Misdiagnosis eight is treating a sensor fault as a firmware problem. A BIOS update can fix communication trouble between the embedded controller and the charging chip, yet it cannot fix an already open sensor [B-S33][B-S41].
Misdiagnoses Part Three: Mismatch, Fixed Resistors, and Not Detected
Misdiagnosis thirteen is a third-party battery NTC value mismatch. The All About Circuits case is a Dell pack whose sensor went missing, with the seller offering both a 10 kilohm 5 percent and a 100 kilohm 1 percent part, so picking wrongly means a tenfold resistance difference, and the discussion states plainly that it must be the correct sensor, never any part at hand. The consequence is that a 100 kilohm NTC in place of a 10 kilohm NTC makes the system read far below the real temperature, the cold fault direction, so it may keep charging when truly overheating, while a 10 kilohm part in place of a 100 kilohm part reads far above the real temperature, the hot fault direction, refusing charging at once [A-S54][B-S1].
Misdiagnosis fourteen is thinking a hot body means a hot battery. Poor processor or graphics cooling makes the body feel hot, yet battery temperature itself stays normal, and when the sensor reading is normal while the body is hot, the fault sits in the cooling system, not the battery temperature sensor. Misdiagnosis fifteen is thinking calibration can fix a sensor. A full charge and discharge calibration only corrects the gauge percentage reading, and it cannot make an open sensor conduct again, nor bring a drifted divider resistor back to its original value. The Lenovo Vantage Battery Gauge Reset only corrects percentage readings, and when charging behaviour stays unchanged after a reset, sensor measurement should follow [B-S27][B-S32][B-S26][B-S40].
Misdiagnosis sixteen is using a fixed resistor in place of the NTC as a lasting repair. Two 10 kilohm resistors in a divider can hold the sense pin voltage at 50 percent, making the charging chip think temperature is normal, a method the BQ24104 official forum discussion states plainly, yet it kills temperature protection completely, so it can only serve as a brief diagnostic step, never a finished repair. The discussion warns plainly against charging that way for long, since a fixed resistor removes overheat protection, and Bond Battery also warns against bypassing protection circuits. Misdiagnosis seventeen is thinking a lit adapter light means a healthy adapter. The light only proves the adapter has output, never proving voltage, wattage, or recognition signals normal, and when Dell adapter recognition fails, the light can still stay lit while the system shows Unknown and stops charging [A-S31][A-S53][A-S54][B-S33].
Misdiagnoses thirteen to seventeen share mismatch and assumption: third-party NTC mismatch, a hot body, calibration, fixed resistors, and the adapter light. A fixed resistor can only serve as a brief diagnostic step, never a finished repair [A-S54][A-S31][B-S26][B-S33]
Misdiagnosis sixteen is using a fixed resistor in place of the NTC as a lasting repair. The discussion warns plainly against charging that way for long, since a fixed resistor removes overheat protection [A-S31][A-S53].
| Misdiagnosis | Real cause | Measurement clue |
|---|---|---|
| Third-party NTC mismatch [A-S54] | 10 kilohms and 100 kilohms picked wrongly | Measure sensor resistance, tenfold gap |
| Hot body treated as hot battery [B-S27] | Cooling system trouble | Sensor reading normal, body hot |
| Calibration treated as sensor repair [B-S26] | Gauge percentage trouble | Charging behaviour unchanged after reset |
| Fixed resistor treated as lasting repair [A-S31] | Temperature protection killed outright | TS pin voltage fixed at 50 percent, never moving with temperature |
| Lit adapter light treated as healthy adapter [B-S33] | Adapter recognition failure | BIOS shows adapter state Unknown |
Hong Kong Conditions One: Humidity, Commuting, and Summer Heat
Hong Kong annual mean relative humidity runs about 78 percent, on Hong Kong Observatory climate normals for 1981 to 2010, with May to August hot and humid. High humidity speeds oxidation and corrosion at the battery connector, the sensor contacts, and the divider resistor joints, and the corrosion layer raises contact resistance, so the sensor signal breaks off and on, or the sense pin voltage drifts, showing up as charging that comes and goes. The temperature gap between an air-conditioned room and the humid outdoors leaves condensation inside the machine, and the mineral deposits left after it dries can cause tiny shorts or leakage current, disturbing the temperature reading chain [B-S49][B-S33][A-S51].
On commuting vibration, carrying a machine on public transport every day shakes the battery connector for long periods, so poor contact appears sooner than on a machine left on a desk, and a loose sensor signal wire also makes readings jump. A dropped or knocked pack cracks the pack-inside NTC more readily. A laptop in a Hong Kong summer car cabin or inside a backpack can run far past the JEITA hot thresholds of 45 to 55 degrees, and the charging chip pauses charging under JEITA, so charging should resume on its own once the machine cools, and only when it does not resume does the fault count as real [B-S33][B-S49][A-S16][B-S9].
On summer heat, Battery University states plainly that above 30 degrees already counts as elevated temperature, speeding permanent capacity loss, and after one year of storage, a battery held at 100 percent charge at 40 degrees keeps only about 65 percent of capacity, while at 60 degrees and 100 percent charge for three months it keeps only about 60 percent. Those numbers describe storage ageing, not an instant fault, yet they show summer heat already burdens the battery, and when the temperature sensor also reads wrongly, the charging chip cannot even carry out its normal protection correctly [B-S20][A-S15][A-S16].
Hong Kong annual mean relative humidity runs about 78 percent, with May to August hot and humid, commuting vibration loosens connector contact, and a laptop in a summer car cabin or backpack can run far past the JEITA hot thresholds [B-S49][B-S33][B-S20]
On summer heat, Battery University states plainly that above 30 degrees already counts as elevated temperature, speeding permanent capacity loss, and after one year of storage, a battery held at 100 percent charge at 40 degrees keeps only about 65 percent of capacity [B-S20][A-S15].
| Hong Kong factor | Effect | Visible sign |
|---|---|---|
| Annual mean relative humidity 78 percent [B-S49] | Connector and joint oxidation and corrosion | Sensor signal breaks off and on |
| Condensation [B-S49] | Mineral deposits cause tiny shorts | Temperature reading chain disturbed |
| Commuting vibration [B-S33] | Poor connector contact | Readings jump, charging comes and goes |
| Summer heat [B-S20] | Above 30 degrees speeds capacity loss | Charging chip pauses charging under JEITA |
Hong Kong Conditions Two: Local Parts, Third-Party Batteries, and Price Reality
Local parts reality one: maker and third-party packs can carry different NTC values, and when a third-party battery uses the wrong NTC value, say 100 kilohms in place of 10 kilohms, it refuses charging the moment it is fitted, looking exactly like a sensor fault. Local parts reality two: before replacing a pack, model and NTC value must be checked, never judging by shape, plug, and voltage alone, and the B constant must also match, or hot band readings will drift. Local parts reality three: maker packs for some older models may be discontinued, so the sensor parameters of a third-party substitute must be checked one by one, and when they cannot be checked, the written quote after inspection should decide, never a guess [A-S54][B-S1][A-S3].
On local parts supply, 10 kilohm NTC parts such as the 103AT-2, NCP18XH103, and ERTJ1VG103 are general parts with ample supply, yet a pack-inside NTC is often a custom wired assembly with a plug, not a single SMD part, so the target NTC package, lead length, and connector type must be confirmed before repair. On winter cold, Hong Kong indoor temperature can fall below 15 degrees in winter, and together with NTC drift, the charging chip may misjudge the battery as below T2, 10 degrees, and cut current, so a user feels winter charging runs specially slowly, while the battery itself is healthy [A-S5][A-S13][A-S15][A-S16].
On price reality, an NTC sensor fault touches the battery pack or mainboard chip-level repair, and the price must follow the real inspection result, with only four confirmed prices: battery from HK$580, screen from HK$1,280, mainboard chip-level repair from HK$880, and keyboard from HK$480, while the exact figure for NTC related repair follows the written quote after inspection. The shop sits at Room 1209, Dali Plaza, Shek Mun, Sha Tin, telephone +852 2186 8010, WhatsApp +852 6558 6806, opening hours 12:00 to 19:00 [A-S54][A-S53].
Before replacing a battery pack, model and NTC value must be checked, never judging by shape, plug, and voltage alone, and the B constant must also match, or hot band readings will drift. Only four prices are confirmed, with the rest by written quote after inspection [A-S54][B-S1][A-S3]
On local parts supply, 10 kilohm NTC parts such as the 103AT-2, NCP18XH103, and ERTJ1VG103 are general parts with ample supply, yet a pack-inside NTC is often a custom wired assembly with a plug [A-S5][A-S13].
Repair or Replace Decision Framework
Option one is replacing the battery pack, when the sensor sits inside the pack. It fits when connector measurement proves the sensor open, shorted, or far from the expected resistance, and fitting a known good battery restores charging. The new pack model, NTC value of 10 or 100 kilohms, and B constant must match the original machine, with third-party batteries checked one by one, never judged by shape and plug alone. The limit is that a pack-inside sensor cannot be replaced alone, so replacing the pack also replaces cells, protection board, and sensor together. When the cells themselves stay healthy, that option means replacing a whole pack for one sensor, which may not be the cheapest cost, yet it is the only safe pack-inside repair method [B-S21][A-S54][A-S53].
Option two is mainboard chip-level repair for a board NTC or divider resistor. It fits when the pack sensor measures normally, a known good battery leaves the fault unchanged, and the sense pin voltage looks abnormal while the sensor itself is healthy, pointing at a drifted board divider resistor, a damaged board NTC, or a broken sense trace. The repair covers replacing drifted divider resistors, replacing the board NTC, and fixing sense traces or connector joints, all inside mainboard chip-level repair. The risk is that resistor values must be checked against that model circuit diagram, since the BQ24616 design values of RT1 2.2 kilohms and RT2 6.8 kilohms fit that design only, never as general values, and a wrong resistance shifts the JEITA thresholds [B-S8][A-S29][B-S48].
Option three is replacing the battery connector or flex. It fits when connector pins are oxidised, bent, loose, or the flex is broken, so the sensor signal breaks off and on, and shaking the battery flex while charging comes and goes is the typical clue. The iFixit guide warns to take care pulling a battery connector out, since fine pins bend easily, and the ThinkPad X1 Carbon 9th generation uses no flex at all, with a direct snap connector, so the removal method differs. Option four is embedded controller or firmware repair. It fits when the sensor, divider resistors, and connector all measure normally, yet charging behaviour stays abnormal, or when an embedded controller reset, clearing CMOS, embedded controller, and real-time clock, makes the fault vanish. The work covers updating BIOS or embedded controller firmware, resetting the embedded controller, checking and closing wrong charge limit settings, and reinstalling the ACPI battery driver. The boundary is that firmware repair cannot bring a damaged sensor or divider resistor back, and when the fault stays after an update, board-level measurement should follow [B-S33][B-S44][B-S39][B-S41].
Option five is replacing the mainboard. It fits when the mainboard embedded controller, charging chip surroundings, or several places are damaged, or key parts are discontinued, while the battery pack itself proves healthy on inspection. The misjudgement trap is that a BIOS showing adapter state unknown does not always mean a dead mainboard, since the fault may sit in the adapter recognition pin or DC jack, so the sense pin and related points should be checked with a multimeter before replacing a board. Option six is replacing the machine. It fits when the machine is old, the pack and mainboard age together, maker parts are discontinued, or repair cost nears the whole machine remaining value. The decision rule is layered exclusion first, NTC body, divider resistors, sense pin voltage, SBS temperature, charging chip itself, and embedded controller settings, before deciding, with every decision backed by measurement point data, never by guessing the NTC is dead, and never using a fixed resistor in place of the NTC for long, since that kills temperature protection completely [B-S33][B-S48][A-S31][A-S53].
The decision rule is layered exclusion first, before deciding, with every decision backed by measurement point data, never by guessing the NTC is dead, and never using a fixed resistor in place of the NTC for long [B-S33][B-S48][A-S31][A-S53]
Option three is replacing the battery connector or flex. It fits when connector pins are oxidised, bent, loose, or the flex is broken, so the sensor signal breaks off and on [B-S33][B-S44].
| Option | When it fits | Key check |
|---|---|---|
| Replace the battery pack [B-S21] | Sensor open, shorted, or far from expected resistance | Model, NTC value, and B constant match |
| Mainboard chip-level repair [B-S48] | Pack normal, TS pin voltage abnormal | Resistor values checked against the circuit diagram |
| Replace the connector or flex [B-S33] | Pins oxidised, bent, or loose | Charging comes and goes when the flex is shaken |
| Embedded controller or firmware repair [B-S39] | All measurements normal yet charging abnormal | Whether the fault vanishes after a reset |
| Replace the mainboard [B-S33] | Several places damaged or key parts discontinued | Measure the TS pin first, never replace a board on a BIOS Unknown alone |
| Replace the machine [B-S22] | Old machine, repair cost near remaining value | Capacity and mainboard state judged together |
Safety: Swollen Battery Plus Temperature Fault
A swollen battery plus a temperature fault is the highest-risk combination: a failed temperature sensor may let the system keep charging while the battery is truly overheating, while swelling itself already means gas forming inside the cells and structure damaged. The signals for stopping use at once are battery swelling, a trackpad or palm rest lifted, a body that will not close, rocking on a desk, abnormal heat, smell, leakage, smoke, or a hissing sound. The right steps are stopping use at once, turning off, and unplugging the adapter, only when safe and without pressing the swollen part, placing the machine on a hard, flat, non-flammable surface, away from paper and bedding, and contacting the maker or a qualified repair channel [A-S16][B-S34][B-S51][B-S52].
The Dell official guidance is that a swollen battery should not be used, and should be replaced and disposed of properly, and when handling it, never squeeze, drop, damage, or pierce the battery, and never try fitting a damaged or swollen battery back into a laptop. The HP community official reply also states plainly that a swollen battery must be removed and replaced, with no other remedy, test, or useful option, and even when HP Support Assistant reports the battery working normally, visible swelling itself is already a clear unsafe signal [B-S34][B-S37].
What must never be done is continuing to charge to see whether it charges, squeezing, piercing, bending, or trying to pry out a stuck battery, putting a swollen battery in ordinary rubbish, or using water on a fire, since smoking or burning means leaving the scene and calling for emergency help. The thermal runaway mechanism is that overcharging and overheating are the final triggers for thermal runaway, with electrolyte breaking down into gas, temperature rising out of control, and smoke or fire following at the end. The special danger of a failed temperature sensor is that when its reading runs low, say an open reading as extreme cold, or the sensor coming away from the cell surface, the system may keep charging at full speed while the battery is truly overheating, raising thermal runaway risk. On Hong Kong recycling, the Environmental Protection Department recycling point map lists places that take rechargeable batteries, including several points in Sha Tin, and swollen or damaged batteries should go to a qualified recycling channel, never ordinary rubbish [B-S18][A-S16][B-S13][B-S50][B-S34].
A swollen battery plus a temperature fault is the highest-risk combination: a failed temperature sensor may let the system keep charging while the battery is truly overheating, while swelling itself already means gas forming inside the cells and structure damaged [A-S16][B-S34][B-S51]
The thermal runaway mechanism is that overcharging and overheating are the final triggers for thermal runaway, with electrolyte breaking down into gas, temperature rising out of control, and smoke or fire following at the end [B-S18][A-S16].
| Signal | What to do | What never to do |
|---|---|---|
| Battery swelling [B-S34] | Stop use at once, turn off, unplug the adapter | Never keep charging to see whether it charges |
| Abnormal heat, smell [B-S51] | Place on a hard, flat, non-flammable surface | Never squeeze, pierce, or bend the battery |
| Smoke, fire [B-S52] | Leave the scene and call for emergency help | Never use water on the fire |
| Swollen battery disposal [B-S50] | Hand to a qualified recycling channel | Never put it in ordinary rubbish |
What a User Can Do Before Sending a Machine In, and Shop Details
Before sending a machine in, a user can let the battery cool to room temperature and try charging again, cross-test with a known good battery of the same model, and note four signs: what temperature the battery shows, what percentage charging stops at, whether the machine only just finished a heavy load, and whether the room is a summer room without air conditioning. Those notes help testing narrow the direction faster. Never open a battery pack on your own. Back up data before sending a machine in, since a sensor fault can shut a laptop down without warning and unsaved work may be lost, and before a firm diagnosis, avoid handling unsaved important work on battery power until charging is trustworthy again [A-S48][B-S33][A-S53].
Passing a maker diagnostic tool test does not mean the sensor is healthy: maker battery tests mainly measure capacity and charge or discharge, and an intermittent sensor fault may never be caught. Before replacing a battery, model and NTC value must be checked, never judging by shape, plug, and voltage alone, and the B constant must also match, or hot band readings will drift. On iFixit safety guidance, discharge the battery below 25 percent before replacing it, take proper precautions when a battery already swells, never bend or flex a battery during replacement, and use only a plastic pry tool, never a sharp tool [B-S35][A-S54][B-S42][B-S43].
The shop sits at Room 1209, Dali Plaza, Shek Mun, Sha Tin, telephone +852 2186 8010, WhatsApp +852 6558 6806, opening hours 12:00 to 19:00. On prices, only four are confirmed: battery from HK$580, screen from HK$1,280, mainboard chip-level repair from HK$880, and keyboard from HK$480, while the exact figure for NTC related repair follows the written quote after inspection. Keep the diagnostic notes with the machine, including the maker diagnostic result and board-level measurement readings, since those records make the next visit faster and let any later fault be compared against a known baseline, instead of starting the whole layered check from nothing again [A-S54][A-S53].
Before sending a machine in, let the battery cool to room temperature and try charging again, cross-test with a known good battery of the same model, note four signs, and never open a battery pack on your own. Back up data before sending a machine in [A-S48][B-S33][A-S53]
Passing a maker diagnostic tool test does not mean the sensor is healthy: maker battery tests mainly measure capacity and charge or discharge, and an intermittent sensor fault may never be caught [B-S35][B-S36].
| Step before sending in | What to do | Purpose |
|---|---|---|
| Cool down and try again [A-S48] | Let the battery cool to room temperature, then try charging | Tell normal JEITA protection from a fault |
| Cross-test [B-S33] | Fit a known good battery of the same model | Tell a pack fault from a mainboard fault |
| Note four signs [B-S33] | Temperature, percentage, load, setting | Help testing narrow the direction faster |
| Back up data [B-S33] | Back up before a firm diagnosis | Avoid losing work to a shutdown without warning |
Limits and Unverified Matters
The task estimate that a 10 kilohm NTC reads about 3.3 kilohms at 50 degrees was checked and found wrong: the Beta equation check gives 3.588 kilohms and the maker resistance-temperature table gives 3.592 kilohms, so the correct number is about 3.59 kilohms, and this guide uses 3.59 kilohms throughout, never 3.3 kilohms. The estimate of about 32.6 kilohms at 0 degrees is correct, with the Vishay B3977 table giving 32.56 kilohms. The JEITA guidance original text could not be checked directly: searching returned only the TI SLYT365 application note retelling of the guidance, including the publication date of 20 April 2007, the ceilings of 4.25 volts and 1 C, and the 175 degree thermal runaway reference point, so JEITA quotations should note the source as the TI SLYT365 retelling [A-S8][A-S7][A-S4][A-S15].
Temperature sense pin static damage has no standalone first-hand source: searching found the TI layout guide general rules for input protection, but no standalone datasheet section or official forum case for sense pin static damage, so this guide lists static only as a mechanism possibility, with no exact static rating or failure rate stated. No general source gives the exact position of a mainboard NTC: different models place the board NTC in different spots, near the charging chip, near the battery connector, or near the processor, and this guide never checked model by model, so it never claims a mainboard NTC always sits in one place [A-S27][A-S26].
How an embedded controller reads a board NTC through its converter, such as ITE or Nuvoton embedded controller converter channel assignment, has no first-hand source: this guide only reaches the embedded controller firmware judgement level, leaving exact embedded controller registers and converter channels for model-by-model checking. Battery connector pin definitions have no unified public standard across brands and models, so sensor pin positions must follow the maker repair manual for that model, and this guide makes no general claim. JEITA threshold temperatures, sense pin reference voltages, and divider resistor values differ by model, and the numbers quoted here, 0, 10, 45, 50, and 60 degrees for the BQ24616, 0, 10, 45, and 55 degrees for the BQ25176J, and 0 and 40 degrees for the LT3650, fit only the chip designs named, never other models [A-S34][B-S8][B-S9][B-S11].
Measured sense pin voltage waveforms and repair case numbers for individual models, such as a common NTC failure rate for a model, have no first-hand source support, so this guide writes no such numbers, and every fault likelihood statement covers mechanism and possibility only, never statistics. The Dedoimedo numbers of stopping charging at 55 degrees, slowing above 50 degrees, and throttling at 75 degrees fit only that author single Slimbook model, never as general thresholds, and the ProSpace20 claim that battery temperature pin voltage is generally about 2 volts comes from a repair blog, not a maker specification. The layer eight 3.3 volt and 10 kilohm divider illustrative calculation is a sense-of-direction example worked out from divider principles, not a measurement specification for any model, and real sense pin voltage must be calculated from that model reference voltage and resistor values. Hong Kong local parts supply changes over time, so quotations should follow the real supply at the time of inspection. Whether a particular Hong Kong repair shop runs sense pin measurement and cross-testing must be asked shop by shop, and this guide makes no guess [B-S32][B-S48][B-S3][A-S52].
On limits, measured numbers for individual models have no first-hand source support, so this guide writes no such numbers, and every fault likelihood statement covers mechanism and possibility only, never statistics [A-S52][B-S32][B-S48]
Measured sense pin voltage waveforms and repair case numbers for individual models have no first-hand source support, so this guide writes no such numbers, and every fault likelihood statement covers mechanism and possibility only, never statistics [A-S52][B-S48].
Frequently Asked Questions
Q1: The adapter is plugged in yet the battery never charges. Does that mean the temperature sensor is dead?
A1: Not necessarily. A temperature sensor fault shows charging that stops only under certain conditions: charging when cold and stopping when hot, charging again after cooling down, or stopping at a percentage that changes each time. When nothing charges at any temperature, the sensor is only one suspect among several, since the adapter, charging chip, fuel gauge, and battery protection board can all be at fault. Check the maker charge limit settings first, then read the Windows and BIOS figures, then cross-test with a known good battery of the same model, and only at the end measure sensor resistance and sense pin voltage [B-S33][A-S53][B-S32].
Q2: Battery temperature shows minus 40 degrees, yet the machine is plainly at room temperature. What causes that?
A2: Most often a pack-inside NTC gone open. When the NTC opens, resistance turns infinite, the sense pin voltage is dragged near REGN, the charging chip reads the temperature as extremely low, and the gauge also reports an extremely low temperature. The way to measure is disconnecting the pack and reading the sensor pins with a multimeter: infinite means open, while a normal 10 kilohm NTC reads about 8 to 12 kilohms at room temperature near 25 degrees. An open can also make the BQ40Z50 record a permanent failure, and that record must be cleared after replacement [A-S28][A-S38][B-S21][A-S54].
Q3: Battery temperature shows above 85 degrees, yet the machine only just started and the battery is cold. What causes that?
A3: Most often a shorted NTC or drifted divider resistors. When the NTC shorts, resistance falls near 0 ohms, the sense pin voltage is dragged near 0 volts, and the charging chip reads the temperature as extremely high. The way to measure is reading the sense pin voltage: near 0 volts points at a short, and reading the NTC body resistance near 0 ohms means a short. Water damp can also cause an equivalent short, which may recover briefly once dry, while corrosion keeps resistance drifting [A-S32][A-S49][A-S53][A-S51].
Q4: Charging grows slower and slower. Does that mean the sensor drifted?
A4: Possibly, but it is not the only cause. NTC drift holds the charging chip in the JEITA current-cutting band for long periods, showing up as charging growing slower and slower, yet the precharge stage of a deeply discharged battery, an adapter with too little wattage, and aged cells all cause slow charging at other layers. The way to tell is watching charge current move with temperature: when cooling restores normal charging speed, the sensor reading high is the suspect, while slowness at every temperature points at the charging chip, adapter wattage, or aged cells. Drift never stops charging outright, it only shifts the whole charging curve [A-S51][A-S18][B-S9][A-S16].
Q5: After fitting a third-party battery, the machine will not charge. Does that mean the mainboard is dead?
A5: Not necessarily. A third-party battery may use the wrong NTC value, say 100 kilohms in place of 10 kilohms, or the wrong B value, say a B3950 in place of the 103AT B3435, and it refuses charging the moment it is fitted, looking exactly like a sensor fault. The way to tell is measuring the third-party battery sensor pins: at 25 degrees the reading should be about 10 kilohms, and when it reads about 100 kilohms, the sensor value is wrong. Before replacing a battery, model, NTC value, and B constant must be checked, never judging by shape, plug, and voltage alone [A-S54][B-S1][A-S3].
Q6: Can a fixed resistor replace the NTC so the machine charges again?
A6: Never as a lasting fix. Two 10 kilohm resistors in a divider can hold the sense pin voltage at 50 percent, making the charging chip think temperature is normal, yet that kills temperature protection completely, so when the battery truly overheats, the system still charges at full speed and thermal runaway risk rises. A fixed resistor can only serve as a brief diagnostic step, never a finished repair. The right way is measuring sensor resistance, divider resistors, and sense pin voltage, locating the fault, and then fitting the correct part [A-S31][A-S53][A-S54][B-S13].
Conclusion
The temperature sensor is small, yet it carries the truth for the whole charging decision chain: it turns battery temperature into resistance, then into voltage, and hands that voltage to the charging chip, the fuel gauge chip, and the embedded controller to judge. When the witness speaks wrongly, both sides decide wrongly. Not charging is not one fault, but the shared face of a failure at any node on the path, and layered diagnosis decides the order of checks: charge limit settings first, then software readings, then cross-testing with another battery, then sensor resistance, then divider resistors and sense pin voltage, and only at the end opening the machine to measure board-level signals. Skipping layers and swapping parts directly is the most expensive and least accurate approach.
Before sending a machine in, note what temperature the battery shows, what percentage charging stops at, whether the machine only just finished a heavy load, and whether the room is a summer room without air conditioning, since those notes help testing narrow the direction faster. Before any work that opens the machine, replaces the battery pack, or touches the mainboard, back up data first. Battery replacement starts at HK$580, mainboard chip-level repair starts at HK$880, with everything else by written quote after inspection. The shop is at Room 1209, Dali Plaza, Shek Mun, Sha Tin, telephone +852 2186 8010, WhatsApp +852 6558 6806, opening hours 12:00 to 19:00. Keep the diagnostic notes with the machine, including the maker diagnostic result and board-level measurement readings, since those records make the next visit faster and let any later fault be compared against a known baseline, instead of starting the whole layered check from nothing again [A-S53][A-S43][B-S33].
Sources
- [A-S1] Murata — Murata NCP18XH103F03RB product search datasheet: 10 kΩ ±1% NTC, B25/50 3380 K ±1%, -40 to 125°C — https://static6.arrow.com/aropdfconversion/dcfdcdc58f3f5e7aa5ea0fcd1af134580e122fae/ncp18xh103f03rb.pdf
- [A-S2] EDN — EDN: NTC Thermistor Beta & Steinhart-Hart Guide — IEC 60539, -2 to -6%/K, Beta vs Steinhart-Hart equations — https://www.edn.com/ntc-thermistor-beta-steinhart-hart-guide/
- [A-S3] The Science 360 — The Science 360: NTC Thermistor Calculation Beta vs Steinhart-Hart — Vishay NTCLE100E3103 B25/85 3977 K, Beta error ±0.4°C, Steinhart-Hart ±0.035°C — https://thescience360.com/ntc-thermistor-beta-equation/
- [A-S4] Vishay — Vishay NTCLE100E3 datasheet (Doc. 29049) pp. 4-6: R-T tables, B25/85 3977 K for 10 kΩ, extended Steinhart-Hart coefficients — https://www.omo-ic.com/pdf/716493/ntcle100e3472jt1-vishay/P4-P6.html
- [A-S5] Semitec — Semitec AT Thermistor datasheet: 103AT-2/3/5, 10.0 kΩ, B25/85 3435 K ±1%, R-T table (27.28 kΩ at 0°C) — https://www.mouser.pe/datasheet/2/362/P12_13_AT_Thermistor-2320347.pdf
- [A-S6] Ametherm — Ametherm Resistance Temperature Curve: R-T factor tables by material curve, Beta 2700-4400 K — http://www.ametherm.com/inrush-current/resistance-temperature-curve
- [A-S7] Ktron — B3950 10K NTC thermistor R-T table: 10 kΩ ±1%, B25/50 3950 K, 3.592 kΩ at 50°C — https://www.ktron.in/wp-content/uploads/2022/11/NTC_10K_3950_Datasheet.pdf
- [A-S8] The Engineering Projects — NTC Thermistor Calculator: Beta equation worked example — 10 kΩ B3950 is 3.588 kΩ at 50°C, divider and self-heating maths — https://www.theengineeringprojects.com/tool/electronics/ntc-thermistor-calculator
- [A-S9] Jameco — Jameco: Temperature Measurement with NTC Thermistors — voltage divider, dissipation constant, Rt from ADC voltage — https://www.jameco.com/jameco/workshop/techtip/temperature-measurement-ntc-thermistors.html
- [A-S10] Wevolver — Wevolver: NTC Thermistor guide — NiMn2O4 spinel ceramic, dissipation constant, divider design, Vishay NTCLE100E3 7 mW/K — https://www.wevolver.com/article/what-is-an-ntc-thermistor-a-guide-to-this-temperature-sensitive-resistor
- [A-S11] Maskset — Maskset: Method for Reading Thermistors — TDK NTCG103JX103DT1 10 kΩ ±0.5%, B25/85 3435 K, R-T table (28.674 kΩ at 0°C), Beta vs Steinhart-Hart fit — https://www.maskset.net/blog/2025/08/02/method-for-reading-thermistors/
- [A-S12] TDK / EPCOS — TDK/EPCOS B573 SMD NTC thermistors datasheet (Jan 2018): 0603 standard series, dissipation factor ~3 mW/K, thermal time constant ~4 s — https://xonstorage.z8.web.core.windows.net/pdf/3175150link.pdf
- [A-S13] Panasonic — Panasonic ERTJ1VG103FM NTC thermistor product page: 10 kΩ 0603 chip NTC, B25/50 3380 K, B25/85 3435 K — https://industrial.panasonic.com/ww/products/pt/ntc-thermistor/models/ERTJ1VG103FM/cad
- [A-S14] Ametherm — Ametherm PANE 103350 NTC thermistor probe datasheet: 10 kΩ ±5%, Beta 3435 K ±2%, TCR -3.90%/°C, dissipation constant 3 mW/°C, 6 s time constant — https://www.ametherm.com/datasheetspdf/PANE103350.pdf
- [A-S15] Texas Instruments — TI Li-ion battery-charger solutions for JEITA compliance (SLYT365): JEITA guidelines of 20 April 2007, notebook T1-T4 bands, 4.25 V / 1 C upper limits, 175°C thermal runaway — https://www.ti.com/lit/an/slyt365/slyt365.pdf?ts=1626228043424
- [A-S16] Battery University / Cadex — Battery University BU-410: Charging at High and Low Temperatures — Li-ion charge 0-45°C, best 10-30°C, no charge below freezing, lithium plating — https://www.batteryuniversity.com/article/bu-410-charging-at-high-and-low-temperatures
- [A-S17] Texas Instruments — TI BQ25882 datasheet (SLVSE40C): 2-cell 2-A boost charger, JEITA thermistor comparator VT1-VT5 as % of REGN, TREG 120°C, TSHUT 150°C, 12 h safety timer — https://www.ti.com.cn/lit/ds/symlink/bq25882.pdf?ts=1784280691338
- [A-S18] Texas Instruments — TI E2E FAQ: how JEITA applies to BQ25882/BQ25883/BQ25886/BQ25887 — TS pin outside T1-T5 suspends charging, JEITA_ISETC / JEITA_ISETH / JEITA_VSET options — https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/1229880/faq-bq25882-how-does-jeita-apply-to-the-bq25882-bq25883-bq25886-and-bq25887-as-it-relates-to-charge-voltage-and-charge-current?tisearch=e2e-sitesearch&keymatch=faq%3Atrue
- [A-S19] Texas Instruments — TI BQ25887 datasheet (SLUSD89B): 2-cell 2-A boost charger with cell balancing, JEITA comparator VT1 73.25% / VT5 34.375% of REGN — https://www.ti.com/lit/ds/symlink/bq25887.pdf?ts=1766655045011&ref_url=http%253A%252F%252Fwww.ti.com%252Flit%252Fgpn%252FBQ25887
- [A-S20] Texas Instruments — TI E2E: BQ25887 EVM TS pin — VT1 73.25% (0°C), VT5 34.375% (60°C) of REGN, 103AT-2 divider example — https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/1038744/bq25887evm-bq25887-evm-ts-pin
- [A-S21] Texas Instruments — TI BQ25618/619 datasheet (SLUSDF8F) viewer: JEITA compliance, 103AT RNTC,T1 27.28 kΩ at 0°C, RNTC,T5 3.02 kΩ at 60°C, programmable T2/T3 — https://www.ti.com/document-viewer/BQ25619/datasheet/GUID-FD2722C0-BE58-414C-9CCD-00F754C63689
- [A-S22] Texas Instruments — TI E2E: BQ25600 JEITA thermistor comparator — TS pin measures voltage not temperature; 103AT + 5.23 kΩ pull-up + 30.9 kΩ parallel gives VT1 73.5% — https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/1317975/bq25600-how-to-understand-the-spec-in-jeita-thermistor-comparator
- [A-S23] Texas Instruments — TI BQ25792 datasheet (SLUSDG1D, rev. Apr 2026): 1-4 cell 5-A buck-boost charger, §8.3.8.5 Thermistor Qualification, JEITA_ISETC / JEITA_VSET, TS_IGNORE — https://e2e.ti.com/cfs-file/__key/communityserver-discussions-components-files/196/0160.SLUSDG1_3D00_4_3D00_TI-PDF_3D00_en_2D00_us-_2800_2_2900_.pdf
- [A-S24] Texas Instruments — TI BQ25756E datasheet (SLUSFF4A, rev. Oct 2026): 1-7 cell bidirectional buck-boost charger, TS pin JEITA profile, 16-bit ADC temperature monitoring — https://www.ti.com/lit/ds/symlink/bq25756e.pdf?ts=1792863076920
- [A-S25] Texas Instruments — TI Charging LiFePO4 Battery and Supercapacitor Using BQ25756 (SLUAAT5): TS pin setting, 103AT NTC divider from REGN, T1-T5 0/10/45/60°C — https://www.ti.com/jp/lit/an/sluaat5/sluaat5.pdf?ts=1765684850876
- [A-S26] Texas Instruments — TI BQ25756 Schematic Checklist: TS pin resistor divider from REGN, 103AT-2 10 kΩ thermistor, JEITA §7.3.4.7.1 — https://e2e.ti.com/cfs-file/__key/communityserver-discussions-components-files/196/5086.BQ25756-Schematic-And-Layout-Checklist.pdf
- [A-S27] Texas Instruments — TI E2E: BQ25672 TS calculation is negative — 103AT + RT1 5.23 kΩ + RT2 30.1 kΩ, datasheet TS equations inconsistent in naming VREF/VREGN — https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/1298449/bq25672-ts-calaculation-is-negative
- [A-S28] Texas Instruments — TI E2E: BQ24610 TS pin — charge suspended when TS is 97% of VREF; valid window is VHTF to VLTF (37% to 73.5% of VREF) — https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/1219788/bq24610-power-management-forum
- [A-S29] Texas Instruments — TI E2E: BQ24616 Temperature Qualification — VT1 70.2-71.4%, 25 ms deglitch for T2/T3/T4, 400 ms deglitch out-of-range TS fault — https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/844866/bq24616-temperature-qualification?tisearch=e2e-sitesearch&keymatch=BQ24616
- [A-S30] Texas Instruments — TI E2E FAQ: BQ2518x TS pin — internal 38 µA current source, tuned for 10 kΩ B(25/85) 3435 K NTC, HOT 60 / WARM 45 / COOL 10 / COLD 0°C, COOL 1/2 or 1/5 current, WARM -100/-200 mV — https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/1603144/faq-bq2518x-how-does-the-ts-pin-work-for-battery-temperature-monitoring
- [A-S31] Texas Instruments — TI E2E: BQ24104 disable thermistor sensing — place TS between VLTF and VHTF (73.5% to 34.4% of 3.15 V VTSB, i.e. 2.32-1.08 V); two 10 kΩ resistors give 50% — https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/1031946/bq24104-disable-thermistor-sensing
- [A-S32] Texas Instruments — TI E2E: BQ24210 unused TS pin — tie TS correctly; below 85% of VTSB can look like a hot battery, 30% of VTSB (~0.66 V) holds normal operation — https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/121056/bq24210---unused-ts-pin
- [A-S33] Texas Instruments — TI E2E: BQ25883/BQ25882 understanding TS_ADC readings — 10 kΩ NTC (Panasonic ERTJ1VG103FA), TS_ADC % vs temperature, 60% ≈ 23.5°C, 36% ≈ 57°C — https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/838328/bq25883-bq25882-understanding-ts_adc-readings
- [A-S34] Texas Instruments — TI E2E: BQ24770 Smart Battery — BQ24770 has no TS pin and cannot monitor battery temperature on its own; paired gauge/EC supplies temperature — https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/981081/bq24770-smart-battery/3625313
- [A-S35] Texas Instruments — TI bq40z50-R1 datasheet (SLUSCB3): 1-4 series pack manager, TS1-TS4 with integrated 18 kΩ pull-up for 10 kΩ (103) NTC, Open Thermistor Permanent Failure — https://www.ti.com/lit/gpn/BQ40Z50-R1
- [A-S36] Texas Instruments — TI bq40z50-R2 datasheet (SLUSCS4C): 1-4 series pack manager, TS1-TS4 pull-up 14.4-21.6 kΩ, JEITA charge control, temperature protections — https://www.ti.com/lit/gpn/BQ40Z50-R2
- [A-S37] Texas Instruments — TI BQ40Z50-R5 Technical Reference Manual (SLUUCN4B): §2.8-2.13 temperature protections, four external thermistors + internal sensor, min/max cell temperature rules — https://www.ti.com/lit/ug/sluucn4b/sluucn4b.pdf
- [A-S38] Texas Instruments — TI bq40z50-R1 Technical Reference Manual (SLUUBC1C): §3.24 Open Thermistor Permanent Fail, §4.2 Charge Temperature Ranges (JEITA) — https://www.ztztechnology.com/pdf-9c/BQ40Z50RSMR-R1.pdf
- [A-S39] Texas Instruments — TI BQ28Z610 datasheet (SLUSAS3D) viewer: §8.3.8 external temperature sensor, TS1 with internal 18 kΩ pull-up for 10 kΩ NTC (Semitec 103AT-2), internal sensor -2.0 mV/°C — https://www.ti.com/document-viewer/BQ28Z610/datasheet/GUID-E01A8099-CE6A-4900-8223-92C57F5FDA0C
- [A-S40] Texas Instruments — TI BQ28Z610-R1 datasheet (SLUSE07B): 1-2 series gas gauge, TS1 18 kΩ pull-up, 103AT-2, temperature measurement calibration — https://www.ti.com/lit/gpn/bq28z610-r1
- [A-S41] Texas Instruments — TI BQ77915 product page: 3-5 series stackable protector, over-temperature / under-temperature charge and discharge, OTC 45/50°C, OTD 65/70°C — https://www.ti.com/product/BQ77915
- [A-S42] Texas Instruments — TI BQ77915 datasheet (SLUSCU0L): temperature thresholds based on 103AT NTC + 10 kΩ pull-up to VTB, UTC threshold 75.06-78.32% of VTB — https://www.ti.com/lit/ds/symlink/bq77915.pdf?ts=1774838482102
- [A-S43] SBS Implementers Forum — Smart Battery Data Specification Rev. 1.1 (Dec 1998): §5.1.9 Temperature() (0x08), 0.1°K units, typical -20 to +75°C, ±3°K accuracy, 0.5°K granularity — https://s3-us-west-1.amazonaws.com/ptab-filings%2FIPR2022-00110%2F1029
- [A-S44] Texas Instruments — TI E2E: BQ30Z554-R1 SMBus 0x08 vs 0x72 — 0x08 returns cell temperature (average of enabled TS sensors); 0x72 returns Int/TS1-TS4/Cell/FET temperatures — https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/946162/bq30z554-r1-difference-between-smbus-commands-0x08-and-0x72
- [A-S45] Microsoft Learn — Microsoft Learn: IOCTL_BATTERY_QUERY_INFORMATION — BatteryTemperature is a ULONG in 10ths of a degree Kelvin — https://learn.microsoft.com/en-us/windows/win32/Power/ioctl-battery-query-information
- [A-S46] Microsoft Learn — Microsoft Learn: EFI_BATTERY_CHARGING_PROTOCOL.GetBatteryInformation — BatteryTemperature in 10ths of a degree Kelvin — https://learn.microsoft.com/en-us/windows-hardware/drivers/bringup/efi-battery-charging-protocolgetbatteryinformation
- [A-S47] CheckBatteryHealth — CheckBatteryHealth: Laptop Battery Temperature guide — battery sensor vs CPU/SSD temperature, Lenovo 5-35°C operating / 10-35°C optimal charging, Dell G15/G16 over-temperature protection above 50°C, powercfg report has no standard temperature field — https://www.checkbatteryhealth.com/blog/laptop-battery-temperature
- [A-S48] Lenovo — Lenovo ThinkPad Yoga user manual: battery cannot be charged when too hot — turn off, cool to room temperature, then recharge — https://www.manualsdir.com/manuals/470259/lenovo-thinkpad-yoga.html?page=126
- [A-S49] Dell — Dell Latitude CPi A user manual: battery indicator flashing alternately green and amber means battery too hot to charge; charge only at normal room temperature — https://www.manualsdir.com/manuals/619644/dell-latitude-cpi-a.html?page=62
- [A-S50] HP Support Community — HP Support Community: laptop runs hot and does not hold a charge — charging system will not engage while hot, resumes when computer cools down — https://h30434.www3.hp.com/t5/Notebook-Hardware-and-Upgrade-Questions/laptop-runs-hot-and-does-not-hold-a-charge/td-p/7233051
- [A-S51] OCT Sensors — OCT Sensors Technical Notes: NTC thermistors typically <0.02°C thermometric drift per year below 50°C; stability depends on humidity, excessive temperature and thermal shock — https://ww.octsensors.com/ntc04/technical/TechnicalNote.htm
- [A-S52] Zentriad — Zentriad: Thermistor Aging and Drift — drift from ceramic/metallisation ageing, accelerated-ageing specs (e.g. % shift after hours at elevated temperature) — https://zentriad.com/thermistor-aging-and-drift-how-to-ensure-long-term-measurement-accuracy/
- [A-S53] Bond Battery — Bond Battery: How to Diagnose and Repair a Laptop Battery Safely — BMS monitors temperature, thermistor near cells, charging stops when temperature input is out of range — https://bondbattery.com/article/repair-laptop-battery-safely/
- [A-S54] All About Circuits — All About Circuits forum: Dell 48 Wh battery circuit issue — lost pack thermistor, must be the correct 10 kΩ thermistor, wrong value bricks the pack — https://forum.allaboutcircuits.com/threads/dell-48wh-battery-circuit-issue.143861/
- [A-S55] Getac — Getac S510 manual: charging will not start if pack internal temperature is below 0°C or above 50°C; charging stops above 60°C; high-temperature charge capped at 80% — https://manualstech.ams3.cdn.digitaloceanspaces.com/html/nl/getac/s510/html/s51044.page
- [B-S1] Murata — Murata NCP15XH103 NTC thermistor datasheet: 10k ohm at 25C, B-constant 3380K, -40 to +125C - Murata — https://datasheet.octopart.com/NCP15XH103E03RC-Murata-datasheet-76796312.pdf
- [B-S2] Vishay BCcomponents — Vishay NTC Thermistors Application Note (Document 29053): temperature protection in battery management / charging - Vishay BCcomponents — https://docslib.org/doc/4203298/the-engineers-guide-to-temperature-sensing
- [B-S3] TDK Electronics — Digital Readout and Trimming of NTC Thermistors, Application Note 2024 - TDK Electronics — https://www-eproc.newark.com/site/binaries/content/assets/common/product-family-documents/tdk-robokit1-dk/tdk-robokit1-dk-digital-readout-and-trimming-of-ntc-thermistors-an1.pdf?ICID=I-FP-DEV-DKHQ-TDK-ROBOKIT1-DK-TR
- [B-S6] Amphenol Advanced Sensors — Amphenol Thermometrics Type FL Low Profile NTC Temperature Sensor datasheet: 10k ohm, B(25/85) 3936K, battery pack temperature sensing - Amphenol Advanced Sensors — https://nz.mouser.com/datasheet/3/59/5/AAS_920_754A_Thermometrics_FL_NTC_TempSensor_091719_web.pdf
- [B-S8] Texas Instruments — BQ24616 JEITA-Compatible Standalone Battery Charger datasheet (SLUSA49C): TS pin VT1-VT5 thresholds, 103AT thermistor, RT1 2.2k / RT2 6.8k - Texas Instruments — https://www.ti.com/lit/gpn/bq24616
- [B-S9] Texas Instruments — BQ25176J Battery Charger datasheet: JEITA thresholds Hot 55C, Warm 45C, Cool 10C, Cold 0C; 103AT-2 NTC - Texas Instruments — https://www.ti.com/document-viewer/BQ25176J/datasheet/GUID-2E26DCB1-3A4F-4A90-8BF2-49F456D691D2
- [B-S10] Texas Instruments — BQ25303J Standalone 1-Cell Battery Charger with JEITA battery temperature monitoring - Texas Instruments — https://www.ti.com/product/BQ25303J
- [B-S11] Analog Devices / Linear Technology — LT3650 Li-ion Battery Charger datasheet: NTC pin, 10k B=3380 thermistor, fault above 1.36V (0C) or below 0.29V (40C) - Analog Devices / Linear Technology — https://www.omo-ic.com/pdf/428137/LT3650EDD-4-2-TRPBF/P7-P9.html
- [B-S13] Texas Instruments — BQ24295: Thermistor - thermistor losing thermal contact reports a lower temperature than actual - TI E2E support forums — https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/736369/bq24295-thermistor
- [B-S14] Analog Devices — MAX17320 2S-4S ModelGauge m5 EZ Fuel Gauge datasheet: die temperature, 4 thermistors +/-1C, JEITA charging prescriptions - Analog Devices — https://static6.arrow.com/aropdfconversion/2022021bbe794b720e7d0d19e325090597b84bf8/max17320.pdf?utm_source=trustedparts&
- [B-S15] Electronic Design — Add Simple Temperature Monitoring To Battery-Management Systems (NTC thermistor divider, -20C to 60C output range) - Electronic Design — https://www.electronicdesign.com/technologies/components/electromechanical/article/21750479/add-simple-temperature-monitoring-to-battery-management-systems
- [B-S16] Linux Kernel Mailing List — Re: ncpXXxh103 compensation values? - Linux kernel NTC thermistor compensation tables (Murata NCP15XH103) - spinics / LKML — https://www.spinics.net/lists/kernel/msg2222434.html
- [B-S17] Justia Patents — Dual Use Thermistor for Battery Cell Thermal Protection and Battery Pack Overcharge/Undercharge Protection (US 20040212350) - Justia Patents — https://patents.justia.com/patent/20040212350
- [B-S18] Battery University / Cadex — BU-409: Charging Lithium-ion (temperature rise ~5C normal, discontinue use if rise exceeds 10C) - Battery University / Cadex — http://www.batteryuniversity.com/article/bu-409-charging-lithium-ion/
- [B-S20] Battery University / Cadex — BU-808: How to Prolong Lithium-based Batteries (above 30C is elevated temperature; storage capacity table) - Battery University / Cadex — https://www.batteryuniversity.com/article/bu-808-how-to-prolong-lithium-based-batteries/
- [B-S21] Battery University / Cadex — BU-911: How to Repair a Laptop Battery (most common thermistor 10k NTC, reads 10k at 20C; locate with ohmmeter, warm by hand) - Battery University / Cadex — http://www.batteryuniversity.com/article/bu-911-how-to-repair-a-laptop-battery/
- [B-S22] Microsoft Learn — Powercfg command-line options (/batteryreport, /output, /duration) - Microsoft Learn — https://learn.microsoft.com/en-us/windows-hardware/design/device-experiences/powercfg-command-line-options
- [B-S23] Microsoft Support — Use Smart charging in Windows (heart icon, Fully Smart charged) - Microsoft Support — https://support.microsoft.com/en-us/windows/experience/power-battery/use-smart-charging-in-windows
- [B-S24] Microsoft Q&A — Charging Battery - Plugged in, Not Charging (uninstall ACPI battery drivers, restart) - Microsoft Q&A — https://learn.microsoft.com/en-us/answers/questions/2854615/charging-battery
- [B-S25] Microsoft Q&A — Microsoft ACPI Compliant Control Method Battery Driver (uninstall via Device Manager, scan for hardware changes) - Microsoft Q&A — https://learn.microsoft.com/en-us/answers/questions/2660467/microsoft-acpi-compliant-control-method-battery-dr
- [B-S26] Microsoft Q&A — Battery not charging on Lenovo laptop Windows 10 (Lenovo Vantage charge limit cap, battery gauge reset) - Microsoft Q&A — https://learn.microsoft.com/en-us/answers/questions/3256338/battery-not-charging-on-lenovo-laptop-windows-10
- [B-S27] PC Hardware Pro — HWiNFO64 Tutorial: How to Know and Monitor Your PC (Sensors mode, Smart Battery Designed vs Full Charged Capacity) - PC Hardware Pro — https://www.pchardwarepro.com/en/tutorial-hwinfo64-guia-completa-para-conocer-y-monitorizar-tu-pc/
- [B-S28] NirSoft — BatteryInfoView: new utility that displays battery information on laptops and netbooks - NirSoft Blog — https://blog.nirsoft.net/2011/07/05/new-utility-that-displays-battery-information-on-laptops-and-netbooks/
- [B-S29] UMA Technology — BatteryInfoView: Free Utility to Show Status and Information (Temperature field = battery pack temperature as reported by the battery sensor) - UMA Technology — https://umatechnology.org/batteryinfoview-free-utility-to-show-status-and-information-about-laptop-and-netbook-battery/
- [B-S30] Cyberciti — upower command in Linux with examples (upower -e, upower -i battery_BAT0) - nixCraft / Cyberciti — https://www.cyberciti.biz/faq/linux-upower-command-examples-and-syntax/
- [B-S31] Linux Uprising — 3 Tools To Display Linux Laptop Battery Information From the Command Line (upower, acpi -V, battop; temperature field) - Linux Uprising — https://www.linuxuprising.com/2021/05/3-tools-to-display-linux-laptop-battery.html
- [B-S32] Dedoimedo — Laptop and battery pending charge issue (battery will not charge above 55C, slow-charge above ~50C; single Slimbook model observation) - Dedoimedo — https://WWW.Dedoimedo.com/computers/laptop-power-charging-not-charging.html
- [B-S33] Dell Support — How to Troubleshoot Dell Laptop Battery Issues (BIOS F2 battery health, AC adapter Unknown, Primarily AC Use 50-80%) - Dell Support — https://www.dell.com/support/kbdoc/en-an/000123069/how-to-troubleshoot-dell-laptop-battery-issues?lang=en
- [B-S34] Dell — Handling swollen Lithium-ion batteries (discontinue use, discharge by unplugging AC, do not crush/drop/puncture, approved recycling) - Dell — https://downloads.dell.com/manuals/common/Swollen_Battery_TechSheet.PDF
- [B-S35] HP — Complete HP Laptop and Accessory Charging Troubleshooting Guide (hard reset, battery health diagnostics, powercfg /batteryreport) - HP — https://www.hp.com/nz-en/tech-takes/laptops/troubleshooting/hp-device-not-charging-troubleshooting-guide.html
- [B-S36] HP Support Community — HP PC Hardware Diagnostics UEFI (Esc then F2, Component Tests, Battery test, 24-digit Failure ID) - HP Support Community — https://h30434.www3.hp.com/t5/Notebook-Boot-and-Lockup/HP-PC-Hardware-Diagnostics-UEFI/m-p/9326119
- [B-S37] HP Support Community — Swollen Battery? (HP Notebook PCs - Swelling or Deformation of Notebook Battery; remove and replace, no other remedy) - HP Support Community — https://h30434.www3.hp.com/t5/Notebook-Hardware-and-Upgrade-Questions/Swollen-Battery/td-p/8016690
- [B-S38] Lenovo Support — Conservation mode (battery kept within 75%-80% when constantly plugged in) - Lenovo Support — https://download.lenovo.com/pccbbs/pubs/legion_slim_5/html_en/EN/common_topics_2022-8_RTM_updated/intro_battery_mode_conservation.html
- [B-S39] Lenovo Support — Yoga 9i 2-in-1 User Guide: Stay energetic (charge temperature 10-35C, no recharge above 95%, recharge allowed at 94% or lower; check battery temperature in Vantage) - Lenovo — https://download.lenovo.com/pccbbs/pubs/yoga_9_2_in_1_14imh9/user_guide/en/help-center-stay-energetic.html
- [B-S40] TechDows — [Solved] Lenovo laptop plugged in but not charging (Conservation Mode / Smart charge caps, emergency reset hole, battery gauge reset) - TechDows — https://techdows.com/solved-lenovo-laptop-plugged-in-but-not-charging.html
- [B-S41] RottenWiFi — ASUS Laptop Not Charging? Fix 60%, 80% and Plugged-In Issues (MyASUS Battery Care Mode 60/80%, 95-100% pause normal, MyASUS System Diagnosis battery checkup) - RottenWiFi — https://blog.rottenwifi.com/why-is-my-asus-laptop-not-charging-when-plugged-in-troubleshooting-the-issue/
- [B-S42] iFixit — Dell XPS 13 9333 Battery Replacement (discharge below 25% before disassembly, swollen battery precautions) - iFixit Repair Guide — https://www.ifixit.com/Guide/Dell+XPS+13+9333+Battery+Replacement/104837
- [B-S43] iFixit — Lenovo ThinkPad T480 Internal Battery Replacement (disable internal battery first, do not bend or flex the battery) - iFixit Repair Guide — https://www.ifixit.com/Guide/Lenovo+ThinkPad+T480+Internal+Battery+Replacement/139942
- [B-S44] iFixit — ThinkPad X1 Carbon Battery Replacement (power off, unplug AC, disconnect battery cable with plastic pry tool) - iFixit Repair Guide — https://www.ifixit.com/Guide/ThinkPad+X1+Carbon+Battery+Replacement/96710?revisionid=1058824
- [B-S46] All About Circuits — Old 5 pin Ni-MH laptop battery confusion (temperature sensing bead, thermistor ~10-25k, decreases when held; thermal fuse in series) - All About Circuits Forum — https://forum.allaboutcircuits.com/threads/old-5-pin-ni-mh-laptop-battery-confusion.133900/
- [B-S48] ProSpace20 — Battery Not Charging Problem! Don't Replace It Before Watching This (NTC thermistor readings, BIOS thermal protections, battery temperature pin voltage typically ~2V from divider) - ProSpace20 — https://www.prospace20.com/2025/05/battery-not-charging-problem-dont.html
- [B-S49] Hong Kong Observatory — Monthly Meteorological Normals for Hong Kong (annual mean relative humidity 78%, 1981-2010) - Hong Kong Observatory — https://www.weather.gov.hk/en/cis/normal/1981_2010/normals.htm
- [B-S50] Environmental Protection Department, HKSAR — Map of Recycling Points (Rechargeable Batteries collection points, including Sha Tin) - Environmental Protection Department, HKSAR — https://www.wastereduction.gov.hk/en-hk/recycling-map?f%5B0%5D=category%3A2036&f%5B1%5D=category%3A2038&f%5B2%5D=category%3A2041&f%5B3%5D=district%3A2005&f%5B4%5D=district%3A2020&f%5B5%5D=material%3A2027&f%5B6%5D=material%3A2033&page=4
- [B-S51] Oregon State Fire Marshal — Rechargeable Battery Safety (stop using on swelling/leaking/smoke; do not puncture, crush, or continue charging; do not charge a damaged, swollen, leaking, unusually hot, or recalled battery) - Oregon State Fire Marshal — https://www.oregon.gov/osfm/education/pages/battery-safety.aspx
- [B-S52] City of Scottsdale Fire Department — Lithium-Ion Battery Safety (warning signs: swelling, heat, smell; stop charging if battery becomes unusually hot or swells; call 911 if smoking/burning) - City of Scottsdale Fire Department — https://www.scottsdaleaz.gov/fire/safety-awareness/lithium-ion-battery-safety/
Need Professional Laptop Repair?
Laptop King has 15+ years of repair experience in Shek Mun, Sha Tin. Free diagnosis, transparent pricing, no fix no fee. 180-day warranty for your peace of mind.